18
Always wear personal protective clothing and safety equipment!
c
Design and Function
• We recommend benzine to clean the tool or
its components.
• Do not use solvents or acids, esters (organic
compounds of acids and alcohol), acetone
(ketone), chlorinated hydrocarbons or nitro
carbonic oils to clean the tool. Do not use
chemicals with a low flashing point.
• For after sales service please contact your
distributor/retailer or the HAZET Service
Center.
4. Trouble Shooting
In case of malfunctions, please check
• The compressor installation and air hoses
(check whether the air consumption l/min
and the hose diameter correspond to the
technical specifications of the appliance);
• The compressed air in regard to the
occurence of dust, condensate and rust
particles;
• Whether the air motor is oiled too much.
4. Maintenance and Cleaning
Oiling:
• Pneumatic tools have to be oiled throughout
their whole serviceable life. The motor and
the (ball) bearings need compressed air to
power the tool. As the moisture in the com
pressed air leads to rust of the motor, daily
oiling of the motor is necessary. For this, the
use of an integrated oiler is recommended.
• HAZET 90701 Oiler can be fixed directly to
the pneumatic tool.
Oiling the pneumatic motor manually:
• Disconnect tool from the air supply and
hold with the air inlet showing upwards.
Observe safety advice.
Put 1 or 2 drops of special pneumatic oil
into the air inlet.
• Connect the tool to the air supply; cover
the air exit of the tool with a towel and
operate a few seconds.
• Never use combustible or easily evaporable
liquids, e.g. kerosene, petrol, diesel, etc. to
lubricate the tool.
ATTENTION!
Excess oil in the motor will be
exhausted immediately through the
air exhaust.
CAUTION!
Never point the air exhaust at any per
son or at any object. The air exhaust is
at the rear side of the handle.
Maintenance:
• Before executing any maintenance work,
disconnect the appliance from the air
supply. Observe the security advice.
• If the tool is used daily, there should be
carried out an inspection after every three
months at the latest however after every
1,000 operating hours.
• All damaged or worn parts, such as
Orings, bearings and blades must be
replaced. All moving parts must be oiled.
• Only use spare parts recommended by the
manufacturer, otherwise the warranty will be
void.
• When disposing of components, lubricants,
etc. please take care that the valid regu
lations for environmental protection are
observed.