Use Only Genuine Hayward Replacement Parts.

Assembling and 

Sizing the Rigid Pressure Hose

A

Asssse

em

mb

blliin

ng

g a

an

nd

d S

Siizziin

ng

g tth

he

e R

Riig

giid

d P

Prre

essssu

urre

e H

Ho

osse

1

1..

Open the plastic bag labeled #1 that contains 10 Rigid Hose
Pipes (Part N) and 5 Hose Pipe Couplings (Part 

I

).

2

2..

Lubricate the 5 Hose Pipe Couplings by dunking them in
soapy water.

3

3..

Align the Barbs on the Hose Pipe Coupling with the Tabs on
the Rigid Hose Pipes and snap together. Be sure the black
o-ring does not slip out of the groove on the Hose Pipe
Coupling (if the o-ring is visible through the latch opening
when pipes are snapped together the o-ring has slipped out
of the groove and will leak)

4

4..

Make 5 

S

Se

etts

s

of 

P

Piip

pe

e A

As

ss

se

em

mb

blliie

es

s

by connecting 1 Rigid

Hose Pipe onto each end of the Hose Pipe Couplings.

5

5..

Locate the “Measuring Tape” (packed in Bag #1), secure the
end of the tape marked “Wall Connector End” on the pool
coping immediately above the Universal Wall Fitting.

6

6..

Unroll the Measuring Tape, walk around the pool to the
farthest point along the pool wall from the Universal Wall
Fitting.

At the farthest point from the Universal Wall Fitting hold
the Measuring Tape at the pool edge/coping and read the
number of Pipe Assemblies specified on the tape.

R

Riig

giid

d H

Ho

os

se

e P

Piip

pe

e A

As

ss

se

em

mb

blly

y

M

Me

ea

as

su

urriin

ng

g T

Ta

ap

pe

e

C

Co

on

nn

ne

ec

cttiin

ng

g H

Ho

os

se

e P

Piip

pe

es

s

I

N

a.

N

No

otte

e::

If the measuring tape specifies more than 5 Pipe

Assemblies, you need to purchase the additional Pipe
sections (P/N AX6000HE) from your Authorized Hayward
Dealer.

b. If the measuring tape specifies fewer than 5 Pipe

Assemblies, set the remaining Pipe Assemblies aside these
will not be needed.

R

Re

ec

ctta

an

ng

gu

ulla

arr--S

Sh

ha

ap

pe

ed

d P

Po

oo

oll

K

Kiid

dn

ne

ey

y--S

Sh

ha

ap

pe

ed

d P

Po

oo

oll

A

An

ng

glle

e--S

Sh

ha

ap

pe

ed

d P

Po

oo

oll

Universal Wall Fitting
(Dedicated Line)

Universal Wall Fitting
(Dedicated Line)

Farthest Point

Farthest Point

Universal Wall Fitting
(Dedicated Line)

Farthest Point 

I

N

1 Pipe
Assembly

Summary of Contents for Viio Turbo 5500TC

Page 1: ......

Page 2: ...e the booster pump and is not covered by the Hayward warranty Always disconnect and remove the Viio cleaner and hoses from the pool before cleaning or backwashing the pool filter After cleaning or bac...

Page 3: ...Operating the Viio Cleaner 9 Setting Pressure 9 Large Capacity Debris Bag 10 Correctly Operating Cleaner 11 Cleaner Adjustments 12 Changing Spin Out Frequency 12 Adjusting Spin Out Duration 12 Adjusti...

Page 4: ...ed Warranty Registration Card within 14 days of purchase date or go to www haywardnet com warranty to fill out online Your warranty card is packed in the Owner s Guide and Accessory Pack Important Thi...

Page 5: ...Adjustment Knob F Cam Cap G Rigid Pressure Hose H Hose Float I Hose Pipe Coupling J Hose Swivel See special installation instructions in this manual K Adjustable Wall Quick Connect L Sweep Hose M Wear...

Page 6: ...d vacuum new surface debris before installing the Viio Pools with Excessive Sand Pools with excessive amounts of sand dense debris should be vacuumed manually before installing the Viio The Viper Bag...

Page 7: ...5 5 When installing or re installing the Universal Wall Fitting use Teflon tape on its plastic threads Leave two starting threads on the end of the Universal Wall Fitting un taped 6 6 Screw the Univer...

Page 8: ...he pool coping immediately above the Universal Wall Fitting 6 6 Unroll the Measuring Tape walk around the pool to the farthest point along the pool wall from the Universal Wall Fitting At the farthest...

Page 9: ...to check that the Wall Quick Connect is locked into the Universal Wall Fitting 3 3 To d di is sc co on nn ne ec ct t the hose first turn the Booster Pump and Filtration pump O OF FF F then push the Wa...

Page 10: ...ttached under water and not to be sprayed by the hole in the Setup Pressure Gauge or by the Sweep Hose N Ne ev ve er r point a jet or hose at people or pets Clip the Setup Pressure Gauge to the hose n...

Page 11: ...2 Slide Float Closure off of bag figure 3A 3 Hold open edges apart and shake debris from bag figure 3B 4 Slide Float Closure onto bag Sand dense debris Always empty the Viio bag when sand or heavy de...

Page 12: ...ay not pick up all debris on the first pass but your pool should be clean in 3 hours or less depending on pool size shape and the amount of debris in the pool O Ob bs se er rv ve e V Viiiio o s s o op...

Page 13: ...s for more frequent Spin Outs If Viio rarely needs to back up and Spin Out near an obstacle then a cam with fewer prongs and less frequent Spin Outs will increase effective cleaning time Changing Spin...

Page 14: ...if the sweep hose does not move side to side and just drags behind the cleaner check the Sweep Hose for holes Check for debris behind the adjustment screw or in the jet end of the Sweep Hose Sweep Ho...

Page 15: ...3 Hold open edges apart and shake debris from bag 4 Slide Float Closure onto bag C Cl le ea an ni in ng g t th he e I In n L Li in ne e F Fi il lt te er rs s 1 1 The Hose In Line filter Part Q is loc...

Page 16: ...set the timer so the Booster Pump will not turn on while the Viio cleaner is out of the pool Never operate the Booster Pump without the cleaner connected 2 Disconnect Wall Quick Connect from the Univ...

Page 17: ...16 Use Only Genuine Hayward Replacement Parts Troubleshooting For Technical Assistance Call 1 908 355 7995...

Page 18: ...1 AX6060Z1 Screw 1 4 Type b x 1 1 4 Set of 10 2 AX6060A Pump Volute 3 AX6060UNPAK Union Connector Kit incl 2 ea Union Hose Connector Union Pipe Connector Union Nut and Union O Ring 4 AX6060C Impeller...

Page 19: ...eep Hose 16 AX6000HWA2V Pressure Hose and Top of In Line Filter Assembly 17 AX6000HFA Hose Swivel Assembly 18 AX6000HE Rigid Hose Pipe Section 2 Rigid Pipes and 1 Coupling 19 AX6000HWA1 Wall Quick Con...

Page 20: ...ts 3 This Limited Warranty shall not apply to any injury loss damage defect or malfunction of the CLEANER or failure of the CLEANER to function resulting from any failure to operate or maintain the CL...

Page 21: ...ll of Sale including date of purchase and serial number of the item claimed to be defective the name and address of the PURCHASER and a brief description of the problems defects encountered Call 908 3...

Page 22: ...P N IS55OOTC Rev B 620 Division Street Elizabeth NJ 07207 Phone 908 351 5400...

Reviews: