background image

Page 2

 

 

 

WARNING

 – Read and follow all instructions in this 

owner’s manual and on the equipment.  Failure to follow 

instructions can cause severe injury and/or death.

 

 
 

 

 

WARNING –

 

This product should be installed and serviced only by a qualified professional.

 

 

CAUTION –

 

All electrical wiring MUST be performed by a qualified electrical contractor, and must conform

to local electrical regulations and AS/NZS 3000 Wiring Rules.

 

 

Use of non-Hayward replacement parts voids warranty. 

 

ATTENTION INSTALLER – THIS MANUAL CONTAINS

 

IMPORTANT INFORMATION ABOUT THE 

INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER 

OF THIS PRODUCT.  FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS 

INJURY.

 

 

 

 

CAUTION

 – 

 

 

 

WARNING

 – 

 

 

 

WARNING

 – 

Pool and spa components have a finite life.  All components should be inspected frequently

and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 

This appliance is not intended for use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

This pump is intended for use on permanently installed swimming pools and may also be used

with hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in

or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed

so that it is capable of being readily disassembled for storage and reassembled to its original integrity. Though this

product is designed for out door use, it is strongly advised to protect the electrical components from the weather.

Select a well-drained area, one that will not flood when it rains. It requires free circulation of air for cooling. Do not

install in a damp or non-ventilated location. If installed within an outer enclousere or beneath the skirt of a hot tub or 

spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the motor.

IMPORTANT SAFETY INSTRUCTIONS

 

Before installing or servicing this electrical equipment, turn power supply OFF.   

 

 

 

WARNING 

 

Risk of Electric Shock.

 All electrical wiring must be performed by a

qualified electrical contractor, and must conform to electrical regulations and AS 3000 Wiring

Rules. All electrical circuits must be supplied through a Residual Current Device - RCD

(Safety Switch), with a residual operating current of 30mA. Hazardous voltage can shock, burn

and cause death or serious property damage. To reduce the risk of electric shock, do NOT use

an extension cord to connect unit to the electricity supply.

 

  

 

WARNING 

– 

To reduce the risk of electric shock replace damaged wiring immediately. Locate the power

cord to prevent abuse from lawn mowers, hedge trimmers and other equipment.

 

  

 

WARNING

 – 

Never operate the circulation system at more than (50PSI) 344Kpa maximum.

 

 

 

 

 

WARNING

 –

 

Automatic restart. 

The pump motor is automaticly protected from overload and overheating. 

If such an error occurs the controller will automaticly try to restart the pump. If a power failure occurs while the pump 

is running, it will automaticly restart once the power has been restored.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

TriStar Variable Speed Pump

30-LITINSB004 Rev-B

Summary of Contents for TriStar VS SP3215VS

Page 1: ... calls read this manual carefully and completely The Hayward TriStar Variable Speed Pump is specifically engineered for the demanding requirements of today s in ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor combined with its advanced hydraulic design optimizes the three essiential ...

Page 2: ...nstructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a damp or non ventilated lo...

Page 3: ...OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause sever injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cov...

Page 4: ...ea that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install pump on a level concrete slab or other rigid base to meet all local and national codes Secure pump to base with screws or bolts to further reduce vibration and stress on pipe joints The base must be l...

Page 5: ...ol to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply fresh sealing compound and re install the threaded fitting Note If the pump is being installed using the standard Hayward Universal Union that is supplied with the pump then there is no need to appl...

Page 6: ...e adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scroll through the home screen information when pressed If the DISP FUNC button is held it will enter the controller into configuration mode The and arrow buttons are used to change parameters within conf...

Page 7: ...rough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed for Prime Mode and is displaying pump rpm Press DISP FUNC button once and the Prime Time remaining is displayed with the time decreasing Press DISP FUNC button again and the power being used is display...

Page 8: ...to be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted between 600 rpm and 3000 rpm by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the timer of V3 to be adjusted between 5 minutes...

Page 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the length of the suction line five minutes is not an unreasonable length of time for priming Only close the filter manual air relief valve once a steady stream of water not air or air mixed with water is...

Page 10: ...nt such as heaters skimmers and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommended you check all other equipment water features are functioning as intended For example when running at low speed for daily filtration verify that the water is adequately flow...

Page 11: ...om the seal plate item 15 2 Press the ceramic seat with rubber cup out of the seal plate item 15 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTANT Clean all recesses and parts to be reassembled Inspect gaskets and replace if necessary Seal Impeller and Diffuser Installation 1 Clean and lightly lubricate the motor shaft and seal recess in the seal p...

Page 12: ...nector Kit Includes Union Nut Connector Gasket 2 ea Union Gasket Pump Strainer Housing 2 x 2 with Drain Plugs threaded style Strainer Cover Kit Includes Strainer Cover Lock Ring O Ring Strainer Cover O Ring Strainer Basket Diffuser Screw Diffuser O Ring Diffuser Impeller Screw Impeller Ring Impeller to suit SP3215VS Shaft Seal Assembly Housing O Ring Seal Plate Housing Insert Seal Plate Spacer Kit...

Page 13: ...ed union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If the suction line is blocked contact a qualified repair professional 2 The pool piping is under size Correct the piping size 3 Check for a plugged or restricted discharge line of the filter valve part...

Page 14: ...olved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 Communication Failure From controller Under voltage and Overload Code Variable Speed Drive Error Codes Service Mode When troubleshooting the pump or the pool system it may be useful to run the pump w...

Page 15: ...tar Variable Speed Pump Page 15 30 LITINSB004 Rev B 30 LITINSB004 Rev B Hayward TriStar SP3215VS Pump 0 5 10 15 20 25 0 100 200 300 400 500 600 Flow L min TDH metres 3000 RPM 2400 RPM 1250 RPM Performance curves for Hayward TriStar VS SP3215VS pump ...

Page 16: ...dney Brisbane Perth Email sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2014 Hayward Industries Inc Hayward and TriStar are registered trademarks of Hayward Industries Inc ...

Reviews: