background image

Page 2 of 12                       

SWIMCLEAR CARTRIDGE FILTER                        ISC2027 REV D

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

WWW.HAYWARD.COM

 

 

 

   

READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION 

INSTRUCTIONS.  FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT IN 
SEVERE PERSONAL INJURY OR DEATH.

  

 

 

– SUCTION ENTRAPMENT HAZARD.  

Suction in suction outlets and/or suction outlet covers that are, damaged, broken, cracked, missing, or 
unsecured can cause severe injury and/or death due to the following entrapment hazards: 

Hair Entrapment

- Hair can become entangled in suction outlet cover. 

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is 

damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the 
limb. 

Body Suction Entrapment

- A negative pressure applied to a large portion of the body or limbs can result in an 

entrapment.  

Evisceration/ Disembowelment Entrapment

- A negative pressure applied directly to the intestines through an 

unprotected suction outlet sump or suction outlet cover that is, damaged, broken, cracked, missing, or 
unsecured can result in evisceration/ disembowelment entrapment. 

Mechanical Entrapment

- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be 

caught in an opening of a suction outlet cover resulting in mechanical entrapment. 
 

 - 

TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

 

 

  A minimum of two functioning suction outlets per pump must be installed.  Suction outlets in the same plane 

(i.e. floor or wall), must be installed a minimum of three feet (3’) [1 meter] apart, as measured from near 
point to near point.  

  Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

  Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

  The maximum system flow rate shall not exceed the flow rating of any listed (per ASME/ANSI A112.19.8M-

1987) suction outlet cover installed. 

  Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not 

securely attached. 

  Replace damaged, broken, cracked, missing, or not securely attached suction outlet components 

immediately. 

  In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards 

and CPSC guidelines, follow all National, State, and Local codes applicable. 

 

Installation of a vacuum release system, which relieves entrapping suction, is recommended. 

 

Basic safety precautions should always be followed, including the following: Failure to follow 
instructions can cause severe injury and/or death. 
 

  This is the safety-alert symbol. When you see this symbol on your equipment or in this 

manual, look for one of the following signal words and be alert to the potential for personal 
injury. 

  Warns about hazards that 

could 

cause serious personal injury, death or 

major property damage and if ignored presents a potential hazard. 
 

  

Warns about hazards that 

will 

or 

can 

cause minor or moderate 

personal injury and/or property damage and if ignored presents a potential hazard.  It can 
also make consumers aware of actions that are unpredictable and unsafe. 
 
The 

NOTICE 

label indicates special instructions that are important but not related to hazards. 

 

Summary of Contents for SwimClear C2020

Page 1: ...FECTIVE FILTRATION RATE DESIGN FLOW RATE FT2 M2 GPM LPM C2020 225 20 9 77 291 C3020 325 30 2 122 462 C4020 425 39 5 150 568 C5020 525 48 8 150 568 MAXIMUM WORKING PRESSURE FOR ALL MODELS 50 PSI 3 45 B...

Page 2: ...wall must be installed a minimum of three feet 3 1 meter apart as measured from near point to near point Dual suction fittings shall be placed in such locations and distances to avoid dual blockage by...

Page 3: ...water circulation system verify all system and pump controls are in OFF position and filter manual air relief valve is in OPEN position Verify that upper and lower filter bodies are properly secured...

Page 4: ...firm ground or equivalent Select a well drained area one that does not flood when it rains Position the filter so that the piping connections control valve and winter drain are convenient and accessib...

Page 5: ...om the factory Only qualified pool professionals should service your filter s Manual Air Relief Valve For Qualified pool professionals only If MAR valve needs to be re installed follow this instructio...

Page 6: ...ocking motion and lifting up 3 Clean Cartridge CLEANING CARTRIDGES The Cartridge filter element can be cleaned by pressure washing inside and outside with a garden hose After hosing cartridge for best...

Page 7: ...clamp T Bolt into clamp trunnion and thread spring nut assembly onto clamp T Bolt with spring end towards trunnion 4 Using a 7 8 socket wrench tighten spring nut assembly while tapping outer band of F...

Page 8: ...s You can determine your filter operation schedule based on your pool size and usage Be sure to operate your filtration system long enough each day to obtain at least one complete turnover of your poo...

Page 9: ...0b CX3020DA Top Closure Plate C3020 C4020 10c CX5020DA Top Closure Plate C5020 10d CX3020D4 Top Closure Plate C7000 Series 11a CX800Z4 Air Relief Tube Assy C2020 11b CX3000Z3 Air Relief Tube Assy C302...

Page 10: ...express written authorization of Hayward Pool Products To original purchasers of this equipment Hayward Pool Products warrants its vacuum release systems to be free from defects in materials and workm...

Page 11: ...dress__________________________________________ Address_______________________________________________________ City__________________________ State_________ Zip_______________ Product Purchased ______...

Page 12: ...Page 12 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2027 REV D USE ONLY HAYWARD GENUINE REPLACEMENT PARTS WWW HAYWARD COM...

Reviews: