![Hayward Super Pump® VS Owner'S Manual Download Page 28](http://html1.mh-extra.com/html/hayward/super-pump-r-vs/super-pump-r-vs_owners-manual_2111222028.webp)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 28 of 32
Super Pump VS Variable Speed Pump
IS26115VSP Rev-A
Ref.
No.
Part No.
Description
Qty.
6
SPX1600AA
Pump / Strainer Housing With Gasket
1
7 SPX1600R
Diffuser
Gasket
1
8 SPX2600B
Diffuser
1
9 SPX2607C
Impeller
1
10
SPX1600Z2
Shaft Seal Assembly
1
11 SPX1600T
Housing
Gasket
1
12 SPX2600E5
Seal
Plate
1
13 SPX1600F5
Motor
Mounting
Plate
1
14
SPX0125z44
Motor Cap Screws (Set of 4)
1
15 SPX1600Z4
Housing
Cap
Screw
4
16
SPX2600G1
Mounting Foot (Includes Screws)
1
17
SPX1600Z52
Mounting Foot Screws (Set of 2)
1
18
SPX3400DR4
Motor Drive Display Cover (Cover only)
1
-
SPX3200LCD
Digital Control Interface Assembly
1
-
SPX3400DRKIT
Wall Mount Kit
1
-
SPXHKIT3
Quick Fix Kit (Includes #3, 7, 10, 11 & Jack’s Lube)
1
POWER END
-
SPX26115Z1VSPE
Power End Assembly (Includes #7-14, motor and drive)
1
11.
Troubleshooting
11.1.
General Problems
Motor Will NOT Start:
1.
Make sure the terminal board connections agree with the wiring diagram on the pump data plate label.
2.
Be sure the pump is wired for the available field supply voltage (230VAC).
3.
Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit
breakers, or blown fuses.
4.
Manually check the rotation of the motor shaft for free movement and lack of obstruction. Correct if
necessary.
Motor Shuts OFF:
1.
Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a
qualified professional to verify the electrical connections.
Motor Hums, But Does NOT Start:
1.
Impeller jammed with debris. Have a qualified repair professional open the pump and remove the debris.
Pump Won't Prime:
1.
Empty pump/strainer housing. Make sure the pump/strainer housing is filled with water and the cover o-
ring is clean. Ensure the o-ring is properly seated in the cover o-ring groove. Ensure the o-ring sealing
surface is lubricated with “Jack’s 327” and that the strainer cover is locked firmly in position. Lubricant will
help to create a tighter seal.
2.
Loose connections on the suction side. Tighten the pipe/union connections.
Note:
Any self-priming pump will not prime if there are suction air leaks. Leaks will result in bubbles
emanating from the return fittings on the pool wall.