background image

IMPORTANT SAFETY INSTRUCTIONS

When using this electrical equipment, basic safety precautions should always be followed, including

the following:

READ AND FOLLOW ALL INSTRUCTIONS

 WARNING

 - Read and follow all instructions in this owner’s manual and on the equip-

ment. Failure to follow instructions can cause severe injury and/or death.

 WARNING

 - ELECTRIC SHOCK HAZARD. MOUNTING A LUMINAIRE THAT REQUIRES 

BONDING OR GROUNDING IN THIS NICHE CAN CAUSE SEVERE INJURY AND/OR DEATH. 

DO NOT MOUNT NON-UL LISTED LIGHTS OR ANY LUMINAIRE THAT REQUIRES BONDING 

OR GROUNDING IN THIS NICHE.

 WARNING

 - Risk of Electric Shock. Hazardous voltage can shock, burn, and cause 

death or serious property damage. All electrical wiring MUST be in conformance with ap-

plicable local codes, regulations, and the National Electrical Code (NEC). To reduce the risk 

of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide 

a properly located electrical receptacle. Before working on any electrical equipment, turn 

off power supply to the equipment.

 WARNING

 - Risk of Electric Shock. Opening light can cause shock, burn and severe 

injury. Light has no user serviceable parts inside. Do not open light.

 NOTICE

 - This swimming pool product is UL listed for permanently installed pools or 

spas only. It is not listed for storable pools or spas. Permanently installed pools and spas 

are those constructed in or partially in the ground and all others capable of holding water 

in a depth greater than 42 in (1.07 m). Storable pools and spas are those constructed on 

or above the ground and capable of holding water to a maximum of 42 in (1.07 m).

 WARNING

 - Electrical shock hazard. Damage to wiring can cause severe injury or 

death. To reduce the risk of electric shock replace damaged wiring immediately. Locate 

conduit to prevent abuse from lawn mowers, hedge trimmers and other equipment.

SAVE THESE INSTRUCTIONS

!

!

!

!

!

!

1

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Summary of Contents for Sheer 500

Page 1: ...ED Lighting Owner s Manual Contents Introduction 2 Installation 2 Mechanical 3 Plumbing 5 ELectrical Wiring 6 Operation 10 Maintenance 13 Replacement Parts 13 Warranty 14 1001811 RevA WFS512B6LED WFS548B6LED WFS518B6LED WFS560B6LED WFS524B6LED WFS572B6LED WFS536B6LED WFS584B6LED LFCUS11100 LFCUS11150 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Page 2: ...ion cord to connect unit to electric supply Provide a properly located electrical receptacle Before working on any electrical equipment turn off power supply to the equipment WARNING Risk of Electric Shock Opening light can cause shock burn and severe injury Light has no user serviceable parts inside Do not open light NOTICE This swimming pool product is UL listed for permanently installed pools o...

Page 3: ...d Collar Ext Collar Set Tan 1 Installation Preparation Installation of the Waterfall requires the use of Pump Cartridge filter Do NOT use sand or DE filter Flow control valve Low voltage transformer and optional single gang junction box LED Light control system wall switch or automation control PVC Pipe and 1 in electrical conduit refer to table below Waterfall Length Supply Pipe Size Less than 18...

Page 4: ...in plumbing and electrical lines Note that the length of the waterfall not shown varies depending on model Step 1 Rough in plumbing and electrical lines See overview diagram on page 5 Step 2 Cut a notch in the bond beam and attach a board as shown below Make sure the board is level as it will be used for setting the level of the waterfall 14 00 8 09 4 16 2 08 9 84 4 47 0 61 1 85 Position the board...

Page 5: ... fully cure and then remove the board Step 5 Glue the ext deck lid collar onto the waterfall unit with PVC glue If the Waterfall is installed in a raised wall a 3 PVC pipe can be used to extend the distance between the top of the Waterfall unit and the deck surface allowing access to the LED light 8 Bond Beam Board Mortar Bed Lip Support Waterfall Assembly 3 PVC Extension Pipe Ext Deck Lid Collar ...

Page 6: ...ictured above 2 plumbing is required The Waterfall requires a cartridge filter to be plumbed in the water supply line otherwise debris that gets in the system could damage the Waterfall Do NOT use a sand or DE filter It is recommended to plumb a flow control valve in the water supply line in order to control the flow of water to the Waterfall and achieve the desired water effect If using a variabl...

Page 7: ...for wiring steps Hayward LJBUY00PP1 Junction Box High Voltage from Manual Wall Switch Or Automation Control Relay Low Voltage Transformer LED Light Deck Lid Collar Cover IMPORTANT Transformer junction box MUST be installed above the highest water level in the Waterfall system to prevent water from filling the transformer junction box Total distance of cable between LED Light and Transformer should...

Page 8: ...should not exceed 150 feet Cable runs that are 100 feet or less should use 14 gauge wire and more than 100 feet should use 12 gauge wire Feed the cable through the electrical line from the Waterfall to the junction box or transformer At the junction box or transformer cut the extra cord leaving enough for wiring If using an optional junction box run the cable from the junction box to the low volta...

Page 9: ...other transformers refer to the instructions Be sure to follow all NEC and local codes when wiring From power control To junction box LED light Bonding Wire L1 L2 low voltage connections Neutral Connection white Hot Connection black Ground green Use 14V tap blue USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8 ...

Page 10: ...r an Omni Smart Relay refer to the graphics below Be sure to follow all NEC and local codes when wiring Hot black Connection to transformer Neutral white Connection to transformer Ground green Connection to transformer Omni Standard Relay Wiring Omni Smart Relay Wiring Neutral Line 1 in Load 1 out Neutral Black White Black Red Red White Gray 9 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Page 11: ...e user s personal preference See graphic below Manual Control Power on the pump controlling the Waterfall system and adjust the flow control valve until the ideal water effect is achieved When using a wall switch to control the light the light must be set to UCL Universal ColorLogic mode This will allow the light to be controlled through power cycling The light should already be set to UCL mode fr...

Page 12: ...1 Voodoo Lounge and be synchronized Omni Automation Control When using an Omni controller the light can be set to Omni Direct mode which allows for direct toggling to the selected show color as well as 10 additional fixed color options brightness control and speed control Refer to the Configuration section of your Omni controller manual for instructions on configuring a light and configuring a wat...

Page 13: ...Modes Follow the procedure below to manually change the light mode 1 Turn light on and wait 15 seconds for show color to launch 2 Turn off light for between 11 15 seconds then turn on for 2 seconds 3 Turn off light for between 11 15 seconds then turn on for 2 seconds 4 Turn off light for between 11 15 seconds then turn on for 2 seconds 5 The light should now be blinking white and a color correspon...

Page 14: ...teps below to replace the LED Light assembly in an existing installation 1 Remove power to the Waterfall system 2 Completely drain water from the Watefall system 3 Disconnect light wires from the transformer junction box 4 Remove deck lid and use the light installation tool to unlock the light from the Waterfall 5 Remove the light and pull the cable through the Waterfall unit 6 Install the new lig...

Page 15: ...For more information on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site at www hayward com WARRANTY EXCLUSIONS 1 Material supplied or workmanship performed by others in process of installation 2 Damage resulting from improper installation including installation on pools larger than the pr...

Page 16: ...d trademark of Hayward Industries Inc 2022 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties USE ONLY HAYWARD GENUINE REPLACEMENT PARTS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Reviews: