1. INSTALLATION:
1.1. Transporting the Basket Strainer:
Product should be stored inside factory packaging until product is ready to be installed. Packaged product should be stored indoors, at room
temperature, and out of direct sunlight. Avoid storing packaged product in location where packaging may become wet. Product should be
moved as close to installation site as possible prior to removing from packaging. Do not cut through tape on box any more than necessary to
avoid damaging product. After removing product from carton, care must be taken not to damage product or to allow debris to enter product.
1.2. Mounting the Strainer to Floor or Skid:
Hayward SB-Series Basket Strainers are equipped with a slotted bolt pattern on the base so that the vessel may be directly mounted to a
skid or to the floor. Hayward recommends using 3/8” diameter bolts or studs with flat washers and lock washers for mounting the
vessel. The bolts (or studs) should be torqued to 5 ft-lb in an alternating sequence in order to securely mount the vessel without damaging
the base and to ensure that the vessel is installed as level as possible.
Fig. 1: SB-Series base mounting pad (bottom view) – ½” thru 1”. Fig. 2: SB-Series base mounting pad (bottom view) – 1-1/4” thru 2”.
WARNING
Hayward PVC, CPVC, or GFPP products should NEVER be used or tested with compressible fluids such as compressed air or
nitrogen. Use of PVC, CPVC, or GFPP products in compressible fluid applications may result in product damage, property damage,
personal injury, or even death.
The PVC, CPVC, or GFPP SB Series Strainer is intended for use in liquid service only. Do not attempt to use this product for
controlling air or gases. Use of this product in air or gas service may result in product damage, property damage, personal injury, or
even death.
Hayward PVC, CPVC, OR GFPP products should not be used in services with operating temperature below 10°F.