background image

Page 3 of 12 

                                                                            IS65ING Rev A 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 Pomona, CA   Clemmons, NC   Nashville, TN  

www.haywardpool.com

 

 

 

 - 

WARNING

 - 

Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow 

instructions can cause severe injury and/or death

 WARNING

 

– Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause severe injury 
and/or death due to the following entrapment hazards: 

Hair Entrapment

- Hair can become entangled in suction outlet cover. 

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked, 

missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.  

Evisceration/ Disembowelment 

- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or 

suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment. 

Mechanical Entrapment

- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a 

suction outlet cover resulting in mechanical entrapment.

 

 

WARNING

 

To Reduce the risk of Entrapment Hazards:

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be 
installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’)  [1 meter] apart, as 
measured from near point to near point. 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards and CPSC guidelines, follow all 
National, State, and Local codes applicable. 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 WARNING

 

 

Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction 

outlets can result in an increase potential for suction entrapment as described above.

 

 WARNING – Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material 

can result in an increase potential for suction entrapment as described above.

 

 WARNING – Suction outlet components have a finite life, the cover/grate should be inspected frequently and replaced at 

least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 CAUTION – Components such as the filtration system, pumps and heater must be positioned so as to prevent their being 

used as means of access to the pool by young children.

  

 

WARNING – Never operate or test the circulation system at more than 40 PSI.

 

 

CAUTION – All

 

electrical wiring MUST be performed by a qualified professional, and MUST conform to local codes and 

regulations.

 

 

WARNING – Never change the filter control valve position while the pump is running.

 

 

 

WARNING

 

– Hazardous Pressure.

 

 Pool and spa water circulation systems operate under hazardous pressure during start 

up, normal operation, and after pump shut off.  Stand clear of circulation system equipment during pump start up.  Failure to follow 
safety and operation instructions could result in violent separation of the pump housing and cover, and/or filter housing and clamp 
due to pressure in the system, which could cause property damage, severe personal injury, or death.  Before servicing pool and spa 

water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position.  Before 
starting system pump, all system valves must be set in a position to allow system water to return back to the pool.  Do not change filter control valve 
position while system pump is running.  Before starting system pump, fully open filter manual air relief valve.  Do not close filter manual air relief 
valve until a steady stream of water (not air or air and water) is discharged.

 

 

WARNING –

 

Separation Hazard.

  

Failure to follow safety and operation instructions could result in violent separation 

of pump and/or filter components.  Strainer cover must be properly secured to pump housing with strainer cover lock ring.  Before 
servicing pool and spa circulation system, filters manual air relief valve must be in open position.  Do not operate pool and spa 
circulation system if a system component is not assembled properly, damaged, or missing.  

 

 

WARNING

 

– Electrical

 

Ground motor before connecting to electrical power supply.  Failure to ground pump motor can 

cause serious or fatal electrical shock hazard.

 

 

WARNING – 

Do NOT ground to a gas supply line. 

 

Summary of Contents for Perflex

Page 1: ...mbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or proper...

Page 2: ...Page 2 of 12 IS65ING Rev A USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN www haywardpool com THIS PAGE IS INTENDED TO BE BLANK ...

Page 3: ...terization of the pool spa from the suction outlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increase potential for suction entrapment as described above WARNING Suction outlet components have a finite life the cover grate should ...

Page 4: ...ch can lift water from a lower level a centrifugal must be located below the water line for dependable priming Select a pump with an output rating of between 30 and 100 GPM 114 380 LPM SYSTEM LOCATION 1 Though the system is designed for outdoor use it is advisable to protect electrical components from the weather Select a well drained area one that will not flood when it rains 2 For best pump perf...

Page 5: ... the bump handle down slowly then up briskly Repeat 8 times Open the vent valve under bump cover open the filter drain Note if the filter is installed below the pool water line close the suction and return valves and allow water and dirt to empty completely After the filter has drained and with the drain still open run the pump for a few seconds to flush out any dirt remaining in the bottom of the...

Page 6: ...hrust Washer 2 ECX1014A Shaft kit Includes 15 16 17 1 18 ECX1104 Tube Sheet Top 1 19 ECX1105 Diaphragm Gasket 1 20 ECX1103 Tube Sheet Bottom 1 21 SPX1500Y1 Tube Sheet Nut 16 22a 22b ECX1031 ECX1032 Flex Tube Assembly 13 3 8 EC65 Flex Tube Assembly 16 1 4 EC75 120 120 23 ECX1642215 20 x 1 Hex head Bolt 16 24 SP0723 Ball Type Drain Valve with Nipple 1 25 ECX4220A Elbow Assy w Check Valve 1 26 ECX407...

Page 7: ... then be removed by the filter Live algae on the other hand multiplies so fast that the filter cannot keep up with its growth rate In an active algae situation it may be necessary to regenerate the Perflex filter as frequently as every 2 to 3 hours When correctly used commercial algaecides are effective against algae though algaecides should be used in conjunction with and not as a substitute for ...

Page 8: ...ized or improper wiring 2 Power cut backs or a combination of both Short cycles 1 D E loaded to capacity with pool dirt algae etc 2 Bumping incorrectly 3 Bump handle bent 4 Pump output exceeds design flow rate of filter 5 Presence of algae 1 Bump Drain Recharge 2 Slow down stroke brisk upstroke Repeat 6 times 3 Check and straighten or replace 4 Check GPM LPM output Regulate pump GPM LPM output to ...

Page 9: ...lts Hard bumping 1 Caking of D E under tube sheet Sometimes caused by accumulation of sun tan oils hair or floating particles that bind together in a clay like form 2 Overloaded with D E Sometimes happens when last charge of dirty D E was not properly drained 3 Filter runs too long between bumping 1 Bump Drain Recharge more often and reduce the use of oils 2 Bump Drain Recharge with proper amount ...

Page 10: ...he express written authorization of Hayward Pool Products Inc To original purchasers of this equipment Hayward Pool Products Inc warrants its vacuum release systems to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Filters which become defective during the warranty period except as a result of freezing negligence improper installation use or ...

Page 11: ... Perflex the video It keeps maintenance at a minimum and pool equipment at a maximum Just order Operation and Maintenance Video Part Number EC OM Video 90 and include your check or money order for 9 95 2 50 for shipping and handling and mail to Hayward Pool Products Inc 620 Division Street Elizabeth NJ 07207 Attn Marketing Communications DETACH HERE Fill out completely and mail within 10 days of p...

Page 12: ...Page 12 of 12 IS65ING Rev A USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN www haywardpool com THIS PAGE IS INTENDED TO BE BLANK ...