background image

SPECIFICATIONS

MODEL

NO.

EFFECTIVE

FILTRATION

AREA

DESIGN FLOW RATE

RESIDENTIAL

PUBLIC

PRESSURE LOSS AT

DESIGN FLOW RATE

RESIDENTIAL

PUBLIC

MAXIMUM 

WORKING

PRESSURE

REQUIRED CLEARANCE

SIDE                 ABOVE

EC40

19 ft.

2

1.8 m

2

38

GPM

144

LPM

38

GPM

144

LPM

3

PSI

0.2

BAR

3

PSI

0.2

BAR

50

PSI

3.45

BAR

12 inch 30 cm 18 inch

46 cm

NOTE: ANSI/NSPI-4 Article V, standard for above-ground and
on-ground pools, advises that components such as the
filtration system, pumps and heater be positioned so as to
prevent their being used as a means of access to the pool by
young children.

PARTS

MODEL EC40 SERIES FILTER

REF.

NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22a

22b

23

24

25

26

27

---

NO.

REQ’D.

1

1

1

1

2

1

1

1

1

1

1

2

2

12

12

12

2

1

72

12

12

1

1

1

1

1

1

1

1

PART NO.

EC1006

EC1033B

ECX10344

ECX1321A

ECX1011

ECX1040

ECX1037B

ECX100Z9

ECX4236

ECX4249

ECX1009

ECX9611246

ECX1014

ECX10271

ECX176855

ECX1077

ECX1004

ECX1003

ECX1031

SPX1500N1

SPX1500Y1

SP0723

SPX1022C

EC2708

ECX1005

ECX4077B

ECX1028

ECX1055

ECX1035

DESCRIPTION

Bump Mechanism Cover

Filter Head w/Vent Valve

Filter Body w/Flow Diffuser

Vent Valve w/O-Ring

Thrust Washer

Bump Handle Assembly

Bump Handle Grip

Pivot Pin

Shoulder Screw

Locknut

Bump Shaft

O-Ring

Retainer

Filter Head Screw

Filter Head Nut

Washer

Tube Sheet (Top or Bottom)

Diaphragm Gasket

Flex-Tube™ Assembly

Tube Sheet Screw

Tube Sheet Nut

1-1/2

Ball-Type Drain Valve

Plug w/Gasket

Pressure Gauge

Flow Diffuser

Check Valve

Decal — Operation

Flow Controller

Flex-Tube Nest (Incls. 5, 9,
10, 11, 14 thru 15)

Summary of Contents for Perflex EC40

Page 1: ...ase Keep the filter BUMP handle drain outlet and pressure gauge accessible for convenient operation There is an alternate BUMP handle location on the other side of the filter outlet Instructions for changing the handle position are covered later Position the filter so the tank can drain by gravity PLUMBING Use 1 1 4 or 1 1 2 I D flexible plastic pipe or hose joined with insert fittings and stainle...

Page 2: ...a 22b 23 24 25 26 27 NO REQ D 1 1 1 1 2 1 1 1 1 1 1 2 2 12 12 12 2 1 72 12 12 1 1 1 1 1 1 1 1 PART NO EC1006 EC1033B ECX10344 ECX1321A ECX1011 ECX1040 ECX1037B ECX100Z9 ECX4236 ECX4249 ECX1009 ECX9611246 ECX1014 ECX10271 ECX176855 ECX1077 ECX1004 ECX1003 ECX1031 SPX1500N1 SPX1500Y1 SP0723 SPX1022C EC2708 ECX1005 ECX4077B ECX1028 ECX1055 ECX1035 DESCRIPTION Bump Mechanism Cover Filter Head w Vent V...

Page 3: ...in the starting pressure This is the result of dirt accumulating within the filter and is completely normal CLEANING Cleaning is recommended when the gauge pressure rises more than 10 psi 70 Bar in less than a 24 hour period or when cloudy water returns to the pool for more than 30 seconds after regeneration To clean first stop the pump then move the bump handle down slowly then up briskly Repeat ...

Page 4: ... written authorization of Hayward Pool Products Inc chemical manufacturer s recommendation for superchlorination The algae will quickly become inactive and can then be removed by the filter Live algae on the other hand multiplies so fast that the filter cannot keep up with its growth rate In an active algae situation it may be necessary to regenerate the Perflex filter as frequently as every 2 to ...

Reviews: