background image

Page 3 of 8

 

Jiffy Niche

TM

 SERIES NICHES 

IS0608UA_Rev B

 

GENERAL INFORMATION: 

 

Introduction: 

This manual contains information for the proper installation and operation of the Hayward Jiffy Niche

TM

 series niches.  A qualified 

professional should do installation of the Hayward Jiffy Niche

TM

.  Failure to install according to the instructions will void the warranty. 

 

Features: 

1.  Attractive, injection molded Duralon

TM

 face rim assembly, for corrosion-free performance. 

2.  Fast and simple installation.  Minimal tools required. 
3.  Specially designed wire sealing system, for sealing pool water from conduit pipe. 

 

Important Information Regarding All Models: 

1. Jiffy 

Niche

TM

 underwater lighting fixture housings (Niche) are Underwriters Laboratories (UL) Listed under File E 39338- 

Category WBDT.  These niches are New York City (NYC) Bureau of Electrical Control approved for use with low voltage (12 
volt) lighting fixtures.  U.L. Listed for fresh water, which includes salt pools with a maximum of 3700ppm salt content, and 
complies with 1999 National Electrical Code (NEC). 

2. Jiffy 

Niche

TM

 model SP0608U underwater fixture housings (Niche) are UL Listed only for use with Hayward Submersible Light 

Fixtures: SP0590SL, SP0590HSL, SP0591SL, SP0591HSL, SP0592HSL, SP0532(S)LED, SP0533(S)LED, SP0534(S)LED, 
SP0535(S)LED. 

 

INSTALLATION INSTRUCTIONS: 

 

GENERAL INSTRUCTIONS COMMON FOR ALL MODELS: 

1.  The National Electrical Code (NEC) requires that the top of the light lens be at least 18” below the water level.  Be sure to 

position the niche so that it is in compliance with this requirement.  Some installers position the niche 24” below the 
anticipated water level to avoid any inspection authority issues with this requirement. 

 

SP0608U 

 

A.  For Vinyl Lined Metal Wall, Vinyl Lined Fiberglass Panel, Or Non-Lined 

Fiberglass Pools: 

1.  If not pre-punched by the factory, drill & cut out the wall panel sections as per dimensions below: 

a.  CIRCULAR PANEL CUTOUT: 6” minimum to 6-1/8“ maximum diameter hole. 

2.  After unpacking the niche carton, remove the large lock ring on the backside of the housing assembly. 
3.  For non-lined pools only, install the flange gasket to the backside of the flange on the housing 

assembly by peeling off the paper exposing the adhesive, and pressing it firmly onto the flange. 

4.  If desired, caulk the backside of the housing flange (lined pool) or housing flange gasket (non-lined 

pool) with silicone or other suitable sealing compound. 

5.  Insert the housing assembly through the wall panel section from the interior of the pool. 
6.  Position the grounding bracket towards the TOP (12 O’clock).  (Fig.1) 
7.  Install the large lock ring from the exterior of the pool, with the six (6) holes facing away from 

the pool wall (outward). 

8.  Snug the lock ring by hand while being careful to keep the word “TOP” on the outside of the 

housing towards the TOP (12 O’clock). 

9.  Insert the posts of the installation tool (Hayward P/N SP0608UT) into any two (2) adjacent 

holes on the lock ring. (Fig.2) 

10.  Insert a screwdriver (or similar tool) into either of the two (2) pry-bar slots.  This will be used 

to prevent the housing assembly from rotating during final tightening. (Fig.2) 

11.  While firmly holding the screwdriver in the previous step, use a small 

rubber mallet to strike the tab of the installation tool, rotating the lock 
ring in the clockwise direction to tighten. 

12.  Install conduit fittings as needed.  All Jiffy Niche

TM

 niches are provided 

with two (2) UL Listed Conduit Fittings.  A 1” trade size, 45° sweep 
elbow is provided for the purpose of directing the conduit pipe towards 
the SP0680/SP0681 Listed Junction Box location.  A 1” x ¾” reducer 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

Summary of Contents for Jiffy Niche

Page 1: ...st installed cost The ability to accept PVC over expensive metal conduit enables Jiffy NicheTM to offer true bottom line savings in materials as well as time to install Jiffy NicheTM currently comes in 1 model for vinyl fiberglass pools and spas When paired with Hayward AstroliteTM or Astrolite IITM light fixture you have the best quality and value in a lighting system available anywhere To facili...

Page 2: ...UST be in conformance with all applicable local codes regulations and the National Electric Code NEC Use of non Hayward replacement parts voids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS NICHE THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS I...

Page 3: ...ed Metal Wall Vinyl Lined Fiberglass Panel Or Non Lined Fiberglass Pools 1 If not pre punched by the factory drill cut out the wall panel sections as per dimensions below a CIRCULAR PANEL CUTOUT 6 minimum to 6 1 8 maximum diameter hole 2 After unpacking the niche carton remove the large lock ring on the backside of the housing assembly 3 For non lined pools only install the flange gasket to the ba...

Page 4: ...he liner per the manufacturers instructions c Smooth out any liner wrinkles on the front of the niche flange gasket 18 Align the face ring assembly to the front of the housing assembly with the word TOP on the front of the face ring towards the TOP 12 O clock For vinyl lined pools the housing assembly should be tightly covered by the liner and not visible DO NOT CUT THE LINER AT THIS POINT Instead...

Page 5: ...ications Replacement Parts SP0608U Parts Diagram Parts Listing Ref No Part No Description CTN QTY 1 SPX0608C FACE RING ASSEMBLY 10 2 SPX0608G GASKET 10 3 SPX0608CP CORD SEAL KIT 10 Hayward Pool Products 2008 All rights reserved USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Page 6: ...Page 6 of 8 Jiffy NicheTM SERIES NICHES IS0608UA_Rev B USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Page 7: ...ce department No returns may be made directly to the factory without the express written authorization of Hayward Pool Products To original purchasers of this niche Hayward Pool Products warrants its niche housing to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Niche housing which become defective during the warranty period except as a resu...

Page 8: ...Page 8 of 8 Jiffy NicheTM SERIES NICHES IS0608UA_Rev B USE ONLY HAYWARD GENUINE REPLACEMENT PARTS ...

Reviews: