Introduction

The AQL-CHEM2 is a 120VAC CO

2

 dispense kit designed for use with a Goldline Aqua

Rite Pro chlorinator or Pro Logic pool control.  The AQL-CHEM2-240 is identical to

the AQL-CHEM2, but uses 240VAC.  When used with the AQL-CHEM sensing kit, the

AQL-CHEM2(-240) solves the problem of how to provide low cost pH control for

backyard pools without having to handle acid.  The AQL-CHEM2(-240) is designed to

install on a standard CO

2

 tank and wire directly to the Aqua Rite Pro or Pro Logic.

Using the AQL-CHEM sensing kit, the Aqua Rite Pro or Pro Logic will sense the pH

level and if needed, the AQL-CHEM2(-240) will inject CO

2

  into the pool water.  CO

2

 is

mildly acidic when dissolved in water and will lower the pool's pH slowly without the

safety or health concerns normally associated with harsher acids.

What's Included

The AQL-CHEM2 and AQL-CHEM2-240 includes the following:

-Pressure reducing regulator preset at 50 psi output

-110 VAC (AQL-CHEM2) or 240VAC (AQL-CHEM2-240) solenoid valve with 6' power

cord

-Nylon washer and spare (only use one)

-15' of black UV resistant flexible tubing

-PVC check valve injector

CO

information and availability

The AQL-CHEM2(-240) kit requires the use of  CO

which is supplied in cylinders that

are readily available from various sources.  CO

cylinders are offered in a variety of

sizes. Goldline recommends the use of 20 pound cylinders for most residential pool

applications. The AQL-CHEM2(-240) uses a standard fitting for these tanks. CO

can

be easily found at local and national welding supply or beverage companies.  A quick

search on the web with the keywords “CO

 supply” will yield many companies, some

with hundreds of branch/store locations nationwide.

Installation

Installation

Installing the AQL-CHEM2 or AQL-CHEM2-240 requires the following steps:

-Mount CO

tank using commercially available straps

-Attach the solenoid valve to the CO

tank

-Install the PVC check valve injector to the pool's return plumbing

-Plug the solenoid valve into the pigtail of the Aqua Rite Pro or Pro Logic pool control

-Configure the Aqua Rite Pro or Pro Logic to control the AQL-CHEM2(-240)

This manual assumes that the Goldline AQL-CHEM Chemistry Kit and the pH Dis-

pense Pigtail (included with AQL-CHEM) have already been installed. If not, this will

need to be performed prior to installation. Refer to the AQL-CHEM manual for instal-

lation instructions.

Mount CO

 tank

Mount the CO

tank in an easily accessible location. Straps or brackets can be pur-

chased from the tank supplier and must be used for a secure installation.

Attaching the solenoid valve

The solenoid valve attaches to the CO

tank much like an outdoor gas grill attaches to

a propane tank. With the tank valve off, insert the included nylon washer and screw

the fitting of the AQL-CHEM2(-240) solenoid valve on to the CO

tank.  If the nylon

washer is lost or destroyed, a spare is provided. Keep the tank's valve off until the

entire installation is complete.

Installing the PVC check valve

When installing the PVC check valve, refer to the plumbing overview of the AQL-

CHEM and AQL-CHEM2(-240) shown below.  The PVC check valve must be installed

at the pool's return line DOWNSTREAM of the electrolytic cell and flow switch.

Because mild acid will be dispensed at this location, it should be the last component

installed in the return line before water is allowed to flow back to the pool.  Note that

the injection point must be free of air pockets and should be located at the underside

(or close to the underside) of the pipe.

To install the check valve, perform the following steps:

1.

Turn off pool filter pump.

2.

Drain water from the return line.

3.

Drill a 7/16" hole in the bottom side of the return line AFTER the electrolytic
cell and flow switch.

4.

Tap the hole for a 1/4" NPT. Use caution not to tap tapered threads too deeply.

5.

Apply plumber's tape to check valve threads and screw into tapped hole.  DO
NOT OVERTIGHTEN.

7.

Connect one end of the provided 3/8" flexible hose to the check valve and the

FROM POOL

FROM SPA

RETURN

TO POOL

RETURN
TO SPA

POOL

pH dispense kit

Insert nylon washer
before attaching to tank

PVC check valve

mounted to

underside of pipe

Summary of Contents for Goldline Controls Sense and Dispense Total Pool Chemistry AQL-CHEM2

Page 1: ...il must be wired directly to the pH output on theAqua Rite Pro or the Pro Logic operating with software version 4 00 or later For Pro Logics using software version less than 4 00 the pigtail must be connected to an internal relay in the Pro Logic Installation instructions for the pigtail are provided with the AQL CHEMkit PlugtheAQL CHEM2intothe120VACpigtailortheAQL CHEM2 240intothe240VAC pigtail A...

Page 2: ...to the pigtail of theAqua Rite Pro or Pro Logic pool control Configure theAqua Rite Pro or Pro Logic to control theAQL CHEM2 240 This manual assumes that the Goldline AQL CHEM Chemistry Kit and the pH Dis pense Pigtail included withAQL CHEM have already been installed If not this will need to be performed prior to installation Refer to theAQL CHEM manual for instal lation instructions Mount CO2 ta...

Page 3: ...to the pigtail of theAqua Rite Pro or Pro Logic pool control Configure theAqua Rite Pro or Pro Logic to control theAQL CHEM2 240 This manual assumes that the Goldline AQL CHEM Chemistry Kit and the pH Dis pense Pigtail included withAQL CHEM have already been installed If not this will need to be performed prior to installation Refer to theAQL CHEM manual for instal lation instructions Mount CO2 ta...

Page 4: ...il must be wired directly to the pH output on theAqua Rite Pro or the Pro Logic operating with software version 4 00 or later For Pro Logics using software version less than 4 00 the pigtail must be connected to an internal relay in the Pro Logic Installation instructions for the pigtail are provided with the AQL CHEMkit PlugtheAQL CHEM2intothe120VACpigtailortheAQL CHEM2 240intothe240VAC pigtail A...

Reviews: