background image

1

LED SPOT  LIGHT 

 4 in 1 )

USER MANUAL

Summary of Contents for HYP008F

Page 1: ...1 LED SPOT LIGHT 4 in 1 USER MANUAL ...

Page 2: ...ns 6 3 SETUP 7 Installation Requirement 7 Connection of DMX Signal Wire 8 3 PIN TO 5 PIN CONVERSION CHART 8 4 OPERATIG INSTRUCTIONS 9 Control Panel Functions 9 Menu Map 10 Operating instructions 11 DMX512 Controller Mode 12 DMX512 Channel Values 12 ID Address Instructions 16 Master Slave Control Mode 17 5 A P P E N D I X 1 8 Service Maintenance Guide 18 B l o w o u t D i a g r a m 2 0 ...

Page 3: ... packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is wit...

Page 4: ...t be operated by the professional technician Make sure that the working voltage will not higher or lower than the rated value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable by handle the plug Please be careful when installing the lighting Never touch the ...

Page 5: ...e 230X200X295 mm l N W 2 5Kgs Features l RGBW color mixing with or without DMX controller l 5 distinct dimming curves l User defined program inner optional program l LED display with password protection l Transfer custom programs between fixtures l Operating Modes DMX512 Connection with ID Address Master Slave l DMX Channels STAG col d 11 channels STAG Dimmer RGBW Macro strobe AUTO auto speed dimm...

Page 6: ...6 Product Overview Dimensions Control board DMX IN DMX OUT Hanging bracket floor stand Bracket adjustment knob POWER OUT POWER IN ...

Page 7: ...anging it and make sure the weight of the light is within limits of the hanger l Please make sure without any flammable objects within 0 5m when installing the light l The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage l Block access below the work area and use suitable and stable platform when installing or servicin...

Page 8: ...hen proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifier the signal will not be weakened DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin ...

Page 9: ...yed menu or sets the currently selected value in to the selected function Navigates upwards through the menu list and increases the numeric value when in a function Navigates downwards through the menu list and decreases the numeric value when in a function 4 OPERATING INSTRUCTIONS Control Panel Functions ...

Page 10: ...eive signal from a DMX controller cntl receive signal or Download programs from Master fixture Slave 11 channels D RGBW S 5 channels D RGBW Assign ID address for fixtures Enable or disable ID Upload programs Password required Off meansselect linear dimming or choose dimmer 1 4to control thedimming speed dimming 1of the fastestdimming curves 4 forthe most slowlydimming curve Enables or Disables pas...

Page 11: ...ns upload successful If has mistake it will turns to red color 6 Press MODE on the source unit to exit the upload mode 2 Enable password lock Ü Ü ON OFF Ü ENTER ON enable lock OFF disable lock Enable the password lock control panel in the boot or go into standby automatically take effect this time to operate lamps need to enter your password MODE UP MODE DOWN MODE UP MODE DOWN Ü ENTER 3 Factory re...

Page 12: ...ating program less than 30 steps please set the final step value be 0 4 Repeat step 3 till complete programming 5 Exit program mode by pressing MODE buttons three times DMX512 Controller Mode 1 Setting DMX512 Address Ü 001 512 Access control panel function by pressing MODE until is displayed Press ENTER addor reduce channelsby pressing UP DOWNbetween 001 and512 Press MODE to exit 2 Setting Channel...

Page 13: ...5 Description 0 100 0 100 Or STEP TIME whenCUS 01 10 is activated 0 10 0 Or FADE TIMEwhen CUS 01 10 isactivated 0 100 0 100 Macro color control 00 20Hz No Function Out1 AUTO1 Out2 AUTO2 Out3 AUTO3 Out4 AUTO4 Out5 AUTO5 Out6 AUTO6 Out7 AUTO7 Out8 AUTO8 Out9 AUTO9 Out10 AUTO10 cust1 custom program 1 Cust2 custom program 2 Cust3 custom program 3 Cust4 custom program 4 Cust5 custom program 5 Cust6 cus...

Page 14: ...ID27 ID28 ID29 ID30 ID31 ID32 ID33 ID34 ID35 ID36 ID37 ID38 ID39 ID40 ID41 ID42 ID43 ID44 Id45 VALUE 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 FUNCTION ID46 ID47 ID48 ID49 ID50 ID51 ID52 ID53 ID54 ID55 ID56 ID57 ID58 ID59 ID60 ID61 ID62 ID63 ID64 ID65 ID66 MASTER DIMMER Channels 1 controls the intensity of the currently projected color When the slider is a...

Page 15: ... 1 10 When activating the Auto Custom programs it is then possible to control the Step time and Fade time by using Channels 2 3 respectively Channel 8 has priority over channels 2 7 DIMMER SPEED Channel 10is for selecting the dimmer mode and dimmer speed When channel 9 is not activated then RGBW and Master Dimmer are linear The dimmer modes 1 2 3 and 4 are different speeds of the nonlinear dimming...

Page 16: ...ing UP DOWN buttons 4 Press MODE to exit For every DMX512 address the user can set 66 separate ID addresses ID addressing is a secondary function in DMX512 mode In DMX512 Controller Mode the user can simultaneously control the individual DMX address of all lights and can control the lights which have separate ID address in independent DMX512 Select STAG channel on fixture s control panel Please re...

Page 17: ...ess ENTER select or by pressing UP DOWN buttons Press ENTER and then press MODE to exit You can choose pre set programs the range is o1 10 Or you can choose custom programs the range is o1 10 2 Setting slave machine Access control panel function by pressing MODE until is displayed Press ENTER press UP DOWN buttons until the is displayed Press MODE return to MENU 3 Usage of Master Slave When two or...

Page 18: ...tor Note Keep DMX cables separated from power cables or black lights 5 APPENDIX Service Maintenance Guide Symptom s 1 or more LED s are not illuminating Possible Solution s Clean the fixtureregularly to avoidany such failure This fixture is convection cooled whichmeans that ifthe surface iskept clean and free ofdebris then propercooling will beallowed to occur An LED may have failed resulting in a...

Page 19: ...ol Panel settings for correct addressing Check DMX cables Check polarity switch settings on the controller Check cable connections Call service technician Note In the event of Display PCB failure a replacement PCB can be ordered directly from Our company Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Make sure connector is firmly connected t...

Page 20: ...Metal core PCB assembly Electronic Transformer House power socket Display PCB Display Clear plastic cover Display watertight seal DMX socket Bracket adjustment metal knob Bracket Assembly Part Number 6P00609 4170709 2P00609 50801029 P00606 2P00605 803004 6P00613 5050101 5040201 6P00611 5020119 ...

Reviews: