Haws HWCT8 Quick Start Manual Download Page 6

 

 

10/08 

Model HWCT8 

Page 5 of 7 

 

 

 

 

MAINTENANCE 

 

  Step 1: 

Periodically clean the strainer located inside the valve body. Refer to 5874 Valve 
Manual for more information. 

 

 Step 2:      

The condenser fins on chiller should be periodically cleaned with brush, air hose or 

vacuum cleaner. Care should be taken not to bend or deform the condenser fins. 

 

 

Step 3:      

The chiller temperature control is factory set for 50 °F water under normal conditions. 

For colder water, adjust control clockwise. For warmer water, turn counterclockwise. 
Remove front chiller panel for access to temperature control. After adjustment allow 
unit to cycle off before checking outlet water temperature. 

 
 

TROUBLESHOOTING

 

 

PROBLEM 

 

REPAIR CHECKLIST 

1. 

Insufficient bubbler flow. 

1a.

Check that inlet screwdriver stop valve is in wide-
open position.  

 

 

1b.

Verify minimum 30 psi flowing supply pressure. 

 

 

1c.

Clean strainer.  See 5874 Valve Manual. 

 

 

  d.

Adjust valve to increase flow.  Use front adjust 
screw or see 5874 Valve Manual. 

2. 

Water too warm or cold. 

2a.

Adjust chiller temperature control, clockwise for 
colder water. 

 

FOUNTAIN REPLACEMENT PARTS LIST 

MODEL/PART # 

QUANTITY USED 

DESCRIPTION 

 

 

 

5705 1 

Bubbler 

head 

Strainer waste PCP 

Nut 6-32 clip grille 

- 4 

Screw 6-32 x 3/8” BTN HD 
SOC 

5874 

Complete valve assembly 

 
 
 
 
 

 

 

 
 

 
 
 

 
 
 
 
© 2006 Haws

®

 Corporation – All Rights Reserved 

HAWS

® 

and other trademarks used

 

in these materials are the exclusive property of Haws Corporation. 

Reviews: