10/08
Model HWCT8
Page 5 of 7
MAINTENANCE
Step 1:
Periodically clean the strainer located inside the valve body. Refer to 5874 Valve
Manual for more information.
Step 2:
The condenser fins on chiller should be periodically cleaned with brush, air hose or
vacuum cleaner. Care should be taken not to bend or deform the condenser fins.
Step 3:
The chiller temperature control is factory set for 50 °F water under normal conditions.
For colder water, adjust control clockwise. For warmer water, turn counterclockwise.
Remove front chiller panel for access to temperature control. After adjustment allow
unit to cycle off before checking outlet water temperature.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler flow.
1a.
Check that inlet screwdriver stop valve is in wide-
open position.
1b.
Verify minimum 30 psi flowing supply pressure.
1c.
Clean strainer. See 5874 Valve Manual.
d.
Adjust valve to increase flow. Use front adjust
screw or see 5874 Valve Manual.
2.
Water too warm or cold.
2a.
Adjust chiller temperature control, clockwise for
colder water.
FOUNTAIN REPLACEMENT PARTS LIST
MODEL/PART #
QUANTITY USED
DESCRIPTION
5705 1
Bubbler
head
-
1
Strainer waste PCP
-
4
Nut 6-32 clip grille
- 4
Screw 6-32 x 3/8” BTN HD
SOC
5874
1
Complete valve assembly
© 2006 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used
in these materials are the exclusive property of Haws Corporation.