FITTINGS AND OPERATING INSTRUCTIONS

2075001

-

-

-

-

HCR8.50

Jeannine Ruf

04.03.2013

2/3

No.

Model 

HCR8.50      

Remote Chiller 220Volt

NOTICE:

 

This water cooler must be connected to the water supply using a dielectric coupling.

 

IMPORTANT! INSTALLER PLEASE NOTE.

The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common

procedure. This grounding may be in the building, or may occur away from the building. This grounding

can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste

or an increase in the metal content of the water. This condition is avoidable by using the proper 

materials indicated below.

INSTALLATION

When mounting unit in an open area, to insure proper ventilation, maintain a 102mm (4") 

1.

         clearance from cabinet louvers on each side of cooler. When mounting unit in a cavity or behind a        

         wall maintain minimum space of 102mm (4") on each side, 102mm (4") on the top and a depth of    

         

305mm

 

(12").

Water inlet is 6mm (1/4") O.D. tube. Contractor to supply the connections as required.

2.

Connecting lines to be of unplated copper, thoroughly flushed to remove all foreign matter before

3.

         being connected to cooler. If flushing does not remove all particles, a water strainer should be 

         installed in supply line. This cooler is manufactured in such a manner that it does not in any way

         cause taste, odor, color  or sediment problems

Connect cooler to building supply line with a shut-off valve and install the in-line strainer between

4.

 the valve and cooler.

Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on 

5.

cooler serial plate: 230Volt, 50Hz and 2Amps. Never wire compressor directly to the power supply.

This chiller has been designed for use with potable water ONLY.

6.

START-UP

Open supply line valve.

1.

Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. 

2.

Steady stream assures all air is removed.

Rotate fan to insure proper clearance and free fan action.

3.

Connect to electrical power.

4.