background image

 

 

10/21 

Model H1117LN.8 

    Page 5 of 10 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

INSTALLATION PROCEDURE... 

 

STEP 9: 

Adjust  bubbler  stream  height  using  small  flathead  screwdriver  inserted  through  a 
hole  in  the  center  of  the  push  button  for  increased  flow  turn  clockwise  and  for 
decreased  flow  turn  counterclockwise.  If  flow  problems  arise,  see  troubleshooting 
guide for additional instructions to correct problem. Bubbler stream may lower during 
short break-in period. Set initial stream height a little high to minimize or eliminate the 
need for break-in period readjustment.

 

STEP 10: 

Verify that electrical power  is off and power supply voltage, phase and cycle match 
specifications printed on chiller label.  In accordance with local codes, wire directly to 
incoming lines at internal chiller junction box. Verify that all inner packing is removed 
and  hand  rotate  fan  blade  to  verify  free  rotation.  Reattach  chiller  front  panel.  Turn 
power  on  and  verify  that  chiller  cycles  off  after  water  reaches  proper  temperature. 
Finally check for leaks. 

 

STEP 11: 

Install grille and tighten outer side screws. Verify there is chilled water out of bubbler. 

 

MAINTENANCE 

 

STEP 1:

    Periodically  clean  the  strainer  (Located  inside  push  button  valves  on  model 

H1117LN.8  or  1920  if  also  installed).  Refer  to  5874  Series  Valve  Manual  for  more 
information.  Also,  clean  supply  line  Y-strainer  on  model  1920HO  (when  equipped 
with this optional model). 

 

 

STEP 2: 

The condenser fins on chiller should be periodically cleaned with brush, air hose or    
vacuum cleaner. Care should be taken not to bend or deform the condenser fins. 

 

 

 STEP 3:   

The  chiller  temperature  control  is  factory  set  for  50ºF  water  under  normal      
conditions. For colder water,  adjust  control  clockwise.  For  warmer  water,  turn 
counterclockwise. Remove front chiller panel for access to temperature control. After 
adjustment allow unit to cycle off before checking outlet water temperature.

 

 

 

 

FIGURE 1 

Summary of Contents for H1117LN.8

Page 1: ...t of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general special incidental or consequential damages claimed to arise under the contract of sale Equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to The units also must be used for the purpose for which they were in...

Page 2: ...n equipped with optional Hands Off Bottle Filler model 1920HO Bottle Filler may be mounted on external wall of building provided transformer shall be mounted inside the wall and protected from water per NEC CEC and local code Sensor 1920HO with 1RKHO H 100 277VAC x 9VDC 50 60Hz 5 Watts MAINTENANCE Periodically clean the strainer Located inside push button valves on model H1117LN 8 or 1920 if also ...

Page 3: ...ush tube into the fitting until it bottoms out d To remove depress collet and pull tubing out Tube Sizes O D Tolerance Insertion Depth 1 4 005 11 16 3 8 005 3 4 2 If installing this unit with optional 1920HO Hands Off Model or 1920 a Refer to the 1920 Series manual supplied with model 1920HO or 1920 for detailed installation operation instructions b It is recommended to use Model 6700 Mounting Pla...

Page 4: ...damage from mark Install the s clips in mounting frame using 10 sheet metal screws into pre drilled holes on lower end of each side of frame Tighten 10 screw while holding s clips centered on wall marks Check grille fit by installing grille and partially tightening 6 23 socket head screws through side of grille Ensure proper panel and grille alignment then tighten eight 5 16 18x1 hex head screws S...

Page 5: ...fy free rotation Reattach chiller front panel Turn power on and verify that chiller cycles off after water reaches proper temperature Finally check for leaks STEP 11 Install grille and tighten outer side screws Verify there is chilled water out of bubbler MAINTENANCE STEP 1 Periodically clean the strainer Located inside push button valves on model H1117LN 8 or 1920 if also installed Refer to 5874 ...

Page 6: ...L 1920HO REFER TO 1RKHO H MANUAL FOR EXPANDED LIST PROBLEM REPAIR CHECKLIST 1 Insufficient nozzle flow 1a Check that inlet screwdriver stop valve is wide open Turn counterclockwise or clockwise Direction depends on style of shut off valve b Verify minimum 30 psi flowing supply pressure c Clean supply line Y strainer d Adjust pressure regulator valve to increase flow Loosen locknut and rotate knob ...

Page 7: ...AKDOWN 5745 2021 FV 0006983506 HCR8 MTGFR LG 0002626651 0410000218 0002981127 PARTS BREAKDOWN 1 REF 3 ROTATED 90 INTO VIEW DETAIL A REMOVE INSERT WITH 5 16 HEX SOCKET NOT SUPPLIED 1 NOTES 1 ENSURE TUBE IS DISCONNECTED FROM PUSH BUTTON VALVE BODY PRIOR TO REMOVAL APPLY ONE DROP OF LOCTITE 222MS TO NOZZLE THREADS PRIOR TO FASTENING BACK ONTO BUBBLER HEAD RE ATTACH TUBE TO VALVE 2 ITEMS 13 THRU 17 AR...

Page 8: ...EET 2 FIG 3 WASTE 34 3 4 883mm FOUNTAIN 32 1 2 826mm BUBBLER 39 3 8 972mm NOTES CONTINUED ON SHEET 2 OF 3 IMPORTANT MOUNTING FRAME MUST BE INSTALLED SO THAT LIP OF FRAME SITS AGAINST FINISHED WALL FACE 3 8 OD TUBING INSULATION TEE FITTING SUPPLIED INLINE STRAINER 1 4 OD TUBE X 3 8 OD TUBE INLET SUPPLIED 103 4 272mm 25 635mm SUPPLY MOUNTING FRAME 8 203mm 8 203mm 38 3 4 985mm 1 1 2 38mm APPROVED DRA...

Page 9: ... APPROVED DRAWN PART NUMBER SCALE SHEET OF REVISION DRAWING TYPE SIZE A BY ECN NO PAGE DATE DATE ECN REVISED PER CHK D PAGE Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS ...

Page 10: ...OR BUTTON HEIGHT FOR ADA COMPLIANCE 6 3 4 171mm 5 5 8 143mm 1920HO W HANDS OFF SENSOR SHOWN 1920 W PUSH BUTTON VALVE NOT SHOWN 6700 OPTIONAL FINISH WALL BP32 OPTIONAL IF FOUNTAIN HIGH LOW SIDES ARE REVERSED USE BP32R MOUNTING PLATE BEHIND EXISTING PUSH BUTTON ASSEMBLY SHOWN CAN BE CONVERTED TO HANDS OFF STYLE USING RETRO FIT KIT MODEL 1RKHO H OR 2RKHO H DEPENDING ON CUSTOMER REQUIREMENTS OPTIONAL ...

Reviews: