Haws H1107.8 Installation, Operation & Maintenance Instructions Manual Download Page 5

 

 

03/20 

Model H1107.8 

Page 5 of 7 

 

 

 

 

INSTALLATION PROC

EDURE … 

 
STEP 10: 

Verify that electrical power is off and power supply voltage, phase and cycle match   
specifications printed on chiller label.  In accordance with local codes, wire directly to 
incoming  lines  at  internal  chiller  junction  box.    Verify  that  all  of  the  inner  packing  is 
removed  and  hand  rotate  fan  blade  to  verify  free  rotation.  Reattach  the  chiller  front 
panel. Turn power on and verify that the chiller cycles off after water reaches proper 
temperature. Finally check for leaks. 

 

STEP 11: 

Install grille and tighten outer side screws. Verify there is chilled water out of bubbler. 

 

MAINTENANCE 

 

STEP 1:

  Periodically  clean  the  strainer  located  inside  the  valve  body.    Refer  to  5874  Series 

Valve Manual for more information.   

 

 

STEP 2:

  The condenser fins on chiller should be periodically cleaned with a brush, an air hose 

or  a  vacuum  cleaner.  Care  should  be  taken  not  to  bend  or  deform  the  condenser 
fins. 

 

STEP 3:

 

The chiller temperature control is factory set for 50

 º 

F water under normal 

conditions.  For colder water, adjust the control clockwise. For warmer water, turn 
counterclockwise. Remove front chiller panel for access to temperature control.  
After adjustment allow unit to cycle off before checking outlet water temperature. 

 

TROUBLESHOOTING 

 

PROBLEM 

 

REPAIR CHECKLIST 

1. 

Insufficient bubbler flow. 

1a.  Check that inlet screwdriver stop valve is 

in wide-open position.  

 

 

  b.  Verify minimum 30 psi flowing supply 

pressure. 

 

 

  c.  Clean strainer.  See 5874 Series Valve 

Manual. 

 

 

  d.  Adjust valve to increase flow.  Use front 

adjust screw or see 5874 Series Valve 
Manual. 

2. 

Water too warm or cold. 

  a.  Adjust chiller temperature control, 

clockwise for colder water. 

 

For more information about Haws products, see our website: 

www.hawsco.com

 

 
 

 
 
 
 

 
 
 

© 2020 Haws

®

 Corporation 

– All Rights Reserved 

HAWS

® 

and other trademarks used

 

in these materials are the exclusive property of Haws Corporation. 

Summary of Contents for H1107.8

Page 1: ...e owner or his agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that HAWS shall not be liable for general special or consequential damages claimed to arise under the contract of sale The drinking fountain manufactured by HAWS is warranted to f...

Page 2: ...ment or mineral content is a problem an inlet filter is recommended PLUMBING CONNECTIONS Inlet is 3 8 O D push in type fitting Waste trap outlet is female 1 1 4 IPS ELECTRICAL CONNECTIONS 115VAC 60HZ 4 7 AMPS Chiller wired direct to incoming line by others PARTS LIST MODEL PACKAGE QUANTITY ITEMS INCLUDED MTGFR 7 1 Mounting Frame Required Sold Separately 3 10 Sheet Metal Screws HCR8 1 Chiller H1107...

Page 3: ...ll tubing out Tube Sizes O D Tolerance Insertion Depth 1 4 005 11 16 3 8 005 3 4 1 2 005 7 8 STEP 1 Provide wall opening as detailed in Installation Drawing Frame must be positioned such that frame flanges overlap and butt against finished wall surface Mounting holes are provided for 6 sheet metal screws After frame is positioned in wall swing chiller support tray into position See Installation Dr...

Page 4: ...t side of housing Install fittings supplied on chiller inlet and outlet tubes see Installation Drawing STEP 8 Thoroughly flush supply line to remove all foreign matter Remove the grille and connect the 1 2 IPS supply screwdriver stop not supplied to stub out in wall Place chiller on chiller support tray against right hand side fully to rear with condenser open panel side facing to front Install su...

Page 5: ...brush an air hose or a vacuum cleaner Care should be taken not to bend or deform the condenser fins STEP 3 The chiller temperature control is factory set for 50 º F water under normal conditions For colder water adjust the control clockwise For warmer water turn counterclockwise Remove front chiller panel for access to temperature control After adjustment allow unit to cycle off before checking ou...

Page 6: ...ENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER PART NO C FENNER 10 25 06 15 0002080221 H1107 8 N A 1 1 FV 06 26 20 DP 6 OF 7 PARTS BREAKDOWN 5545 2020 FV PBM1107 0006983506 6462 5703M 5874PBF PBA6 0005982900 HCR8 0002626550 MTGFR 7 BP7 0002981127 PART...

Page 7: ...T REMOVE SCREWS AND THEN SQUEEZE CLIPS ON NUT RETAINER TO POP OUT INSTALL IS REVERSE OF REMOVAL 7 ALIGN HOLES IN CHILLER SUPPORT TRAY WITH HOLES IN FRAME AND FASTEN WITH 10 SHEET METAL SCREWS ADULT STANDING HEIGHT WASTE 34 3 4 883mm SUPPLY 34 5 8 879mm FOUNTAIN 32 1 2 826mm BUBBLER 39 3 8 972mm FRAME 11 5 8 384mm ADULT WHEELCHAIR HEIGHT WASTE 29 1 4 743mm SUPPLY 29 1 8 740mm FOUNTAIN 27 686mm BUBB...

Reviews: