Haws 7778B Installation, Operation & Maintenance Instructions Download Page 2

04/17 

      Model 7778B 

Page 2 of 4 

 

LOCATION OF UNIT:  

The Model 7778B Eye/Face Wash should be installed in close 

proximity to potential accident areas. It should be clearly identified, free from 
obstructions and easy to access. 
 

SUPPLY LINE:  

The minimum recommended line size is 1/2” IPS with 30-90 psi (2-6 

ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter 
is recommended. 
 

PLUMBING CONNECTIONS:  

Inlet supply is female 1/2” IPS. Waste outlet is 1-1/4” 

IPS. 

 

TROUBLESHOOTING 

 

PROBLEM 

 

 

REPAIR CHECKLIST 

1.  No flow. 

1.   

Check the main shut-off valve. 

2.  Insufficient water flow. 

2.  a.  Verify minimum 30psi flowing supply 

line pressure. 

 

 

 

b.  Probable clogging of flow control 

due to inadequate line flushing. 
Unscrew eye/face wash head and 
remove the four screws to 
disassemble head. Clean flow 
control and reassemble head. 

3.  Eye/face wash streams do not 

meet desired eye level. 

3.   

Possible blocked flow control, see 
above solution. Possible non-leveled 
eye/face wash assembly. 

4.  Water does not drain properly. 

4.   

Check the main waste line of your 
building to see if it does handle the 
capacity required for the entire 
drainage system. 

 

 

 

 

For more information about Haws products see our website: 

www.hawsco.com

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© 2017 Haws® Corporation – All Rights Reserved 
HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

 