background image

09/08 

      Model 3202/3202G 

Page 2 of 4 

 

 
 

RECOMMENDED TOOLS: 

Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable 

wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end 
wrench. 
 

LOCATION OF UNIT: 

The Model 3202/3202G Drinking Fountain is a wheelchair accessible 

drinking water facility. The height dimensions shown, meet current ADA requirements. When 
installing this unit, local, state or federal codes should be adhered to. If height other than 
shown is required, then dimensions must be adjusted accordingly. 
 

SUPPLY LINE: 

The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) 

pressure. Where sediment or mineral content is a problem, an inlet filter is recommended. 
 

PLUMBING CONNECTIONS: 

Inlet is 1/4" IPS male fitting.

  

 
MAINTENANCE: 

Periodically clean the strainer. Refer to 5874 Valve Manual for more 

information.

 

 

TROUBLESHOOTING 

 

PROBLEM 

 

REPAIR CHECKLIST 

1.  Insufficient bubbler flow. 

1a.  Check that inlet screwdriver stop valve is in 

wide-open position. 

 

 

  b.  Verify minimum 30 psi flowing supply 

pressure. 

 

 

  c.  Clean strainer.  See 5874 Valve Manual. 

 

 

  d.  Adjust valve to increase flow. Use front  

adjust screw or see 5874 Valve Manual. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© 2006 Haws

®