12/17
Model 3202/3202G
Page 2 of 4
RECOMMENDED TOOLS:
Hack saw, pipe joint sealant, screwdriver, level, 12"
adjustable wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket
wrench or open end wrench.
LOCATION OF UNIT:
The Model 3202/3202G Drinking Fountain is a wheelchair
accessible drinking water facility. The height dimensions shown, meet current ADA
requirements. When installing this unit, local, state or federal codes should be adhered
to. If height other than shown is required, then dimensions must be adjusted
accordingly.
SUPPLY LINE:
The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6
ATM) pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet is 1/4" IPS male fitting.
MAINTENANCE:
Periodically clean the strainer. Refer to 5874 Series Valve Manual
for more information.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. Insufficient bubbler flow.
1a. Check that inlet screwdriver stop valve is in
wide-open position.
b. Verify minimum 30 psi flowing supply
pressure.
c. Clean strainer. See 5874 Series Valve
Manual.
d. Adjust valve to increase flow. Use front
adjust screw or see 5874 Series Valve
Manual.
General Notes:
Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out to
ensure correct engagement with O-Ring.
For more information about Haws products, see our website:
www.hawsco.com
© 2017 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used
in these materials are the exclusive property of Haws Corporation.