Haws 3121FR Installation, Operation & Maintenance Instructions Download Page 2

03/20 

Model 3121FR 

Page 2 of 4 

 

 

RECOMMENDED TOOLS: 

Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable 

wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end 
wrench. 
 

LOCATION OF UNIT:  

When installing Model 3121FR Drinking Fountain, local, state or 

federal codes should be adhered to. If height other than shown is required, then dimensions 
must be adjusted accordingly. 
 

SUPPLY LINE: 

The minimum recommended line size is 1/2

“IPS.  Flowing pressure is 30-90 

psi (2-6 ATM) for Model 3121FR.

 

Where sediment or mineral content is a problem, an inlet 

filter is recommended. 

 
PLUMBING CONNECTIONS:  

Waste outlet is 1-

1/4” IPS. 

 

MAINTENANCE: 

Periodically clean the strainer.

  

Refer to 6518FR Operation and 

Maintenance Sheet for additional information. 

 

TROUBLESHOOTING 3121FR  

 

PROBLEM 

 

REPAIR CHECKLIST 

1. 

Insufficient bubbler flow. 

1a. 

Check that inlet screwdriver stop valve is 
wide open. (Customer supplied). Turn 
counterclockwise.  

 

 

  b. 

Verify minimum 30psi flowing supply 
pressure. 

 

 

  c. 

Adjust valve to increase flow.  See 
6518FR Valve Manual. 

 

 

General Notes: 

Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out to 
ensure correct engagement with O-Ring. 

 
 
 

For more information about Haws products, see our website: 

www.hawsco.com

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© 2020 Haws

®