01/21 1210 Series Bottle Fillers
Page 9 of 17
OPTIONAL BOTTLE FILLER
– ERROR CODE TABLE
TROUBLESHOOTING
Note: If the suggested items in the checklist fail to solve the problem, contact Haws Technical
Support at 1-800-766-5612.
ERROR CODE
REPAIR CHECKLIST
1.
E009
– COMPCY
Compressor is cycling too frequently
a.
b.
c.
d.
Clear error in programming mode and
power cycle unit and check error to validate.
Power cycle unit and ensure fan runs
initially for approximately 10 seconds.
Clean condenser fins of dust and debris.
Verify inlet water and ambient temperatures
are below specification maximum.
2.
E012
– SENOB
Bottle filler sensor is obstructed
a.
b.
c.
Clear error in programming mode and
power cycle unit and check error to validate.
Remove obstruction from aperture
Clean aperture with soft cloth
that won’t
scratch aperture.
Check aperture for excessive scratches
3.
E014
– RFID
RFID board lost communication
a.
b.
Clear error in programming mode and
power cycle unit and check error to validate.
Check cable connection to RFID board.