10/20
MODEL 1119HO/1119HO2
PAGE 2 OF 7
RECOMMENDED TOOLS
: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64
“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open-end
wrench.
LOCATION OF UNIT:
The Model 1119HO/1119HO2 Drinking Fountain is a wheelchair
accessible drinking facility. The height dimensions shown, meet current ADA requirements.
When installing this unit, local, state or federal codes should be adhered to. If height other
than shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE
: The minimum recommended line size
is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet is 3/8” O.D. compression fitting. Waste outlet is female 1-
1/4
” NPT.
ELECTRICAL CONNECTIONS
:
Drinking Fountain may be mounted on external wall of
building provided transformer shall be mounted inside the wall and protected from
water as shown on RKHO Series O&M details (page 8) per NEC/CEC and local code.
Sensor(s)
:
1119HO with RKHO.120/120P
:
120 x 24 VAC, 60Hz, .68 AMPS.
1119HO with RKHO.240
:
240 x 24 VAC, 60Hz, .68 AMPS.
1119HO2 with RKHO.120/120P
:
120 x 24 VAC, 60Hz, 1.36 AMPS.
1119HO2 with RKHO.240
:
240 x 24 VAC, 60Hz, 1.36 AMPS.
MAINTENANCE:
Periodically clean the strainer (Located inside push button valve on Model
1119HO). Refer to 5874 Series Valve Manual for more information.
INSTALLATION PROCEDURE
GENERAL NOTES:
1. For all plastic push-in type fitting connections, only connect NSF-61 copper or
plastic tubing. Stainless steel or glass tubing is not recommended. The
following assembly instructions must be followed to ensure a watertight
connection:
a. Cut tubing square and clean.
b. Mark from end of tube the length of insertion (See table below).
c. Push tube into the fitting until it bottoms out.
d. To remove, depress collet and pull tubing out.
Tube Sizes
O.D.
Tolerance
Insertion Depth
1/4”
±.005”
11/16”
3/8”
±.00
5”
3/4”
1/2”
±.005”
7/8”