10/20 

      MODEL 1119HO/1119HO2 

PAGE 2 OF 7 

 

RECOMMENDED TOOLS

: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable 

wrench, 10" pipe wrench, 5/64

“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open-end 

wrench.

 

LOCATION OF UNIT:

 The Model 1119HO/1119HO2 Drinking Fountain is a wheelchair 

accessible drinking facility. The height dimensions shown, meet current ADA requirements. 
When installing this unit, local, state or federal codes should be adhered to. If height other 
than shown is required, then dimensions must be adjusted accordingly. 

SUPPLY LINE

: The minimum recommended line size 

is 1/2“IPS with 30-90 psi (2-6 ATM) 

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. 

PLUMBING CONNECTIONS:

 

Inlet is 3/8” O.D. compression fitting. Waste outlet is female 1-

1/4

” NPT. 

ELECTRICAL CONNECTIONS

Drinking Fountain may be mounted on external wall of 

building provided transformer shall be mounted inside the wall and protected from 
water as shown on RKHO Series O&M details (page 8) per NEC/CEC and local code.

 

  Sensor(s)

      

1119HO with RKHO.120/120P

:

 120 x 24 VAC, 60Hz, .68 AMPS. 

      1119HO with RKHO.240

:

 240 x 24 VAC, 60Hz, .68 AMPS. 

      1119HO2 with RKHO.120/120P

:

 120 x 24 VAC, 60Hz, 1.36 AMPS. 

      1119HO2 with RKHO.240

:

 240 x 24 VAC, 60Hz, 1.36 AMPS. 

MAINTENANCE: 

Periodically clean the strainer (Located inside push button valve on Model 

1119HO). Refer to 5874 Series Valve Manual for more information. 

 

INSTALLATION PROCEDURE 

 

GENERAL NOTES: 

 

1.  For all plastic push-in type fitting connections, only connect NSF-61 copper or 

plastic tubing. Stainless steel or glass tubing is not recommended. The 
following assembly instructions must be followed to ensure a watertight 
connection: 

a.  Cut tubing square and clean. 
b.  Mark from end of tube the length of insertion (See table below). 
c.  Push tube into the fitting until it bottoms out. 
d.  To remove, depress collet and pull tubing out. 

 

Tube Sizes 

O.D. 

Tolerance 

Insertion Depth 

1/4” 

±.005” 

11/16” 

3/8” 

±.00

5” 

3/4” 

1/2” 

±.005” 

7/8” 

 

 
 
 
 
 

Summary of Contents for 1119HO

Page 1: ...not be liable for the cost of repairs alterations or replacements or for any expense connected therewith made by the owner or his agents except upon written authority from HAWS Sparks Nevada HAWS wil...

Page 2: ...ll of building provided transformer shall be mounted inside the wall and protected from water as shown on RKHO Series O M details page 8 per NEC CEC and local code Sensor s 1119HO with RKHO 120 120P 1...

Page 3: ...r break in period readjustment Model 1119HO 1119HO2 5867 Valve Pressure Regulator Adjust bubbler stream height using the black pressure regulator mounted inside bracket that has HO sensor unit by loos...

Page 4: ...5 REF 3 4 1 STRAINER WASTE ASSY 1 BACK PANEL 2 BUBBLER HEAD ASSY PCP 3 PUSH BUTTON ASSY 4 BUTTON PUSH FLANGED PCP W VALVE 5 PLATE BOTTOM 6 8 9 5703M PBA6 5874PBF PBM1105 0004023580 6462 ITEM DESCRIPT...

Page 5: ...NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AN...

Page 6: ...APPROVED DRAWN PART NUMBER SCALE SHEET OF REVISION DRAWING TYPE SIZE A BY ECN NO PAGE DATE DATE ECN REVISED PER CHK D PAGE Haws Corporation All Rights Reserved HAWS and other trademarks used in these...

Page 7: ...NTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE FV 10 23 20 1 0510001123 D 1119HO 1119HO2 1 14 2 2 FV 10 29 20 5605 SLS 7 OF 7 INSTALLATION 5605 7 OF 7 2020 FV TRANSFORMER ST...

Reviews: