Hawle HAWIDO 1400 Manual Download Page 12

 

-9- 

 

C.  Fault finding 

 
 

Symptoms 

Possible cause 

Action 

Valve does not open 

One-way flow restrictor blocked  Replace or unscrew the set 

screw several times until the 
valve functions properly 

 

One-way flow restrictor closed 
too far 

Loosen the grub screw until the 
valve functions properly 

Valve does not close 

One-way flow restrictor blocked  Replace or screw the grub set 

fully in and out several times, 
and then reset 

 

Filter in control circuit blocked 

Clean the filter 

 

Air in the control lines or valve 
chamber 

Vent system 

 

Foreign matter in the main valve  Carry out a service, and remove 

any foreign matter 

 

Diaphragm defective 

Carry out a service, and replace 
the diaphragm 

 

Valve spindle jammed by 
encrustation  

Carry out service, and remove 
any encrustation 

Loud noises 

Unsatisfactory operational 
conditions 

Change pressure conditions by 
0.1 to 0.2 bar. Slightly open or 
close the one-way flow 
restrictor. Contact Hawle 
customer service department. 

 

Wrong valve diameter 

Calculate correct valve 
diameter. (If necessary contact 
Hawle) 

Erratic operation 

One-way flow restrictor 
incorrectly set 

Reset (according to Chapter: 

Resetting the reaction speed)

 

Original pressure values no 
longer reached 

Pressure gauge faulty 

Check or replace pressure 
gauge 

 

Changed operating conditions 

Reset accordingly (see Chapter: 

Recommended installation)

 

Epoxy-coating damaged 

Transportation damage, 
installation damage 

Repair using Hawle two-
component repair kit for 
coatings 

 
 
 
 

Summary of Contents for HAWIDO 1400

Page 1: ...manual Pressure retention valve DAV with float control...

Page 2: ...HAWIDO REGULATING VALVES Instruction for Pressure sustaining valve with float control Type 1406 ND40 to ND200 Keep this instruction manual at the location of the valve...

Page 3: ...g data and always specify this additional information concerning the valve type pressure and flow ratios whenever you consult or have reason to question the manufacture or supplier Year of manufacture...

Page 4: ...UT OF SERVICE AND MAINTENANCE 10 1 PUTTING OUT OF SERVICE 10 2 MAINTENANCE AND SERVICE 10 2 1 GENERAL 10 2 2 ANNUAL CHECKS 10 2 3 FOUR OR FIVE ANNUAL MAINTENANCE 11 3 REPAIR KITS AND SPARE PARTS 12 3...

Page 5: ...rature range 2 to 40 C 2 General safety guidelines The Hawle HAWIDO regulating valve is designed for use in drinking water supply systems Please consult the manufacturer before using it with other med...

Page 6: ...wards It is recommended that shut off valves be fitted on both sides plus a dirt trap on the inlet side Depending on the installation situation a mounting adapter may also be required If the HAWIDO 14...

Page 7: ...If the inlet pressure is between 4 to 9 bar an orifice is required after the Hawido valve The pressure will be reduced in two steps If the pressure is between 9 to 16 bar a Hawido pressure reducing v...

Page 8: ...levate continuously in the direction of the float control valve but is not to exceed a length of more than 20 m The difference between the height of the float control valve and the main valve is not t...

Page 9: ...l The water level Maximum HAWIDO valve closed and the water level Minimum HAWIDO valve open can be preset with the setting rings These rings may have to be adjusted during the operating mode Setting r...

Page 10: ...l plug on the position indicator Slightly loosen a union of the control circuit at its highest point approximately one turn Loosen the screw on the hand wheel on the control valve 6 and turn the hand...

Page 11: ...Check the pressure on the pressure gauge on the inlet side If the required relief or sustaining pressure has been set tighten the screw on the hand wheel of the control valve Spring Mark Regulating p...

Page 12: ...e Carry out a service and replace the diaphragm Valve spindle jammed by encrustation Carry out service and remove any encrustation Loud noises Unsatisfactory operational conditions Change pressure con...

Page 13: ...ce a year the valve should be checked for correct operation function check Once a year the filters upstream of the valve and in the control lines should be cleaned Every four or five years the inner w...

Page 14: ...nents for wear dirt and scaling Clean inner components seat and inner surfaces including the valve cover Disassembly the spindle guide at the housing rinse the housing interior For valves from DN 40 t...

Page 15: ...valve 2C slowly Valve must close Open the ball valve 2C slowly Valve must open 3 Repair kits and spare parts Several spare parts are required for the four or five yearly maintenance These can be obta...

Page 16: ...13 3 1 Main valve with stainless steel connection ND 40 to ND 200 drawing 08 12 2011 pl...

Page 17: ...Nut INOX 0007 710 080 0007 710 080 0007 712 080 0007 716 080 0007 716 080 12 Spring INOX 1049 050 000 1049 050 000 1049 065 000 1049 080 000 1049 100 000 Spring for valves installed upright position...

Page 18: ...07 724 080 12 Spring INOX 1049 125 150 1049 151 150 1049 200 000 1049 200 000 Spring for valves installed upright position INOX 1050 125 150 1050 151 000 1050 200 000 1050 200 000 13 Spindle guide cov...

Page 19: ...16 3 3 Control valve pressure sustaining stainless steel drawing...

Page 20: ...0 5d Stainless steel 0007 208 050 15 Hexagon socket screw M6 x 45 Stainless steel 0004 506 045 16 O Ring 48 0 x 1 5 NBR70 0180 048 015 17 O Ring 16 x 1 5 NBR 70 0180 016 015 18 Intermediate casing fo...

Page 21: ...2 stainless steel 1 5 mm d12 stainless steel 1 9 mm d12 stainless steel 2 4 mm d12 stainless steel 3 1 mm d18 stainless steel 3 5 mm d18 stainless steel 4 0 mm 0284 006 000 0284 009 000 0284 012 000 0...

Page 22: ...455 016 000 0455 025 000 0455 032 000 0456 Female adaptor elbow union 90 IG 3 8 AG 3 8 stainless steel IG 1 2 AG 1 2 stainless steel IG 3 4 AG 3 4 stainless steel IG 1 AG 1 stainless steel 0456 012 00...

Page 23: ...0600 012 040 0600 012 060 0610 Solenoid valves Solenoid valve normally open 2 2 way valve 1795 96 122K84 Solenoid valve normally closed 2 2 way valve 1795 96 E121K04 Solenoid valve normally open 3 2 w...

Page 24: ...el AG 3 8 L 60 mm stainless steel AG 3 8 L 70 mm stainless steel AG 3 8 L 80 mm stainless steel AG 3 8 L 110 mm stainless steel 0680 012 030 0680 012 040 0680 012 050 0680 012 060 0680 012 070 0680 01...

Page 25: ...tchet with attachment Ratchet with attachment for the one way flow restrictor 1199 000 030 1199 Ratchet with attachment Ratchet with attachment for the one way flow restrictor 1199 000 040 5292 Grease...

Page 26: ...23 12 03 2014 pl...

Page 27: ...6 000 000 1996 000 000 1996 000 000 1996 000 000 Item Description Material Article number DN 125 DN 150N DN 200 DN 250 DN 300 1 Pin Stainl steel 1992 000 125 1992 000 150 1992 000 200 1992 000 250 199...

Page 28: ...Tightening torque Socket bolt 1 Reference Max DRV DAV M 6 A2 A4 70 8 Nm 8 5 Nm MBV RBS Control Hexagon bolt Strenght class Tightening torque valve M 1 Reference Max NAZ M 6 A2 A4 70 8 Nm 8 5 Nm Torque...

Page 29: ...e Telefax 36 0 26 501 502 www hawle hu Hawle Armatury spol s r o Ricansk 375 Telefon 420 0 2 410 03 111 CZ 25242 Jesenice u Prahy Telefax 420 0 2 41 00 33 33 www hawle cz Hawle Sp lka zo o ul Piaskowa...

Page 30: ...27...

Reviews: