Hawle 986-01 Operating And Maintenance Instructions Download Page 2

03/2016

Änderungen vorbehalten

Seite 2 von 2

The axle may only be screwed in to the maximum extent until the 

end is flush with the stop nut.

The correct adjustment is found when the air release stop no 

longer closes during operation venting, but after a short time 

during compressed air flushing.

If the air release stop does not close during the compressed 

air purging, the distance between the sealing cones must 

be reduced. To do this, hold the stop nut as described above 

and turn the axle outwards a few turns counterclockwise. The 

correct adjustment is found if the air release stop does not close 

during operation venting, but closes after a short time during 

compressed air flushing.

After completion of the compressed air purging, the residual 

pressure remaining in the pipeline must be removed through the 

overflow  outlet  to  allow  the  air  release  stop  to  open.  In  order 

to speed up returning to normal operating states, the overflow 

outlet is infinitely variable between 3 mm² and 28 mm².

To do this, unscrew the plastic screw inserted laterally into the 

valve body counter-clockwise using an AF 7 open-end spanner 

(until the black O-ring on the screw becomes visible). Since an 

enlarged overflow outlet automatically means increased air loss 

during the compressed air purge, it should only be set as large 

as necessary to allow it to open in a reasonable amount of time.

5. Maintenance and servicing of the air release stop:

The air release stop must also be checked at least in every valve maintenance. To do this, unscrew the air release 

stop (valve) or remove (set). Check the ease of operation of the shut-off mechanism by slowly pressing on the plug. 

The openings of the overflow screw should be specially checked for contamination and cleaned if necessary. If the 

air release stop is dirty inside, the entire component can be soaked in clean water and then rinsed under running 

water. Disassembly of the air release stop should be avoided as far as possible!

Should it ever be necessary, remove the plastic fixing ring at the outlet and pull out the complete mechanism. The 

valve insert can be disassembled into its individual parts and cleaned by unscrewing the stop nut.

The assembly takes place in reverse order.