Hawker EnerSys LifeSpeed IQ Safety And Use Instructions Download Page 1

ENGLISH

SAFETY INSTRUCTIONS

GOALS OF THIS MANUAL

This manual is aimed at any authorized personnel wanting
to use a 3-phase

LifeSpeed IQ

TM

charger to recharge lead

acid motive power batteries (vented, Hawker XFC

TM

, Gel or

Water Less

®

/Water Less

®

20 ranges)

This manual contains information on:

Charger functionality.

Use and setting of charger parameters.

Technical specifications of the LifeSpeed IQ chargers.

EnerSys

®

intends to provide clear and simple information 

in this manual, and assumes no responsibility for misunder-
standing or improper interpretation of the information.
The owner of the equipment is required to preserve this
manual during the life of the equipment and to transfer said
manual to any subsequent purchaser.

WARRANTY

Warranty is offered by the  manufacturer based on local 
regulations. Please contact your local distributor for further
information.

RECOMMENDATIONS

Recommendations for safe operation

This  manual should be carefully read, prior to using the
equipment, by anyone intending to use the charger. 
The LifeSpeed IQ:

Must not have its air circulation impaired in any way, 
primarily around the air inlet areas. 

Dust accumulation must be removed every 12 months.

Must be used within its protection norms, and never 
be directly in contact with water. 

Must be used only within the temperature range 
specified in the technical specifications. 

Internal connection torques must be checked once a
year.

Must not be installed on a surface subject to high 
vibration levels (proximity of motors, compressors, etc.).

Must not be installed close to the batteries in order to
avoid any gassing that could damage it prematurely.

Must not be installed in arduous environments such as:
•  Harbour applications (saline environment)
•  Close to cold stores
•  External locations with exposure to wind and rain

Operator safety

All proper precautions must be observed when the 
equipment is used in areas where accidents are possible.
Ensure proper ventilation when the charger is used with 
lead-acid batteries, due to gassing. Never disconnect the 
battery during the charging process.

General warnings

Requirements for use:

The equipment must be properly grounded (earthed).

The input voltage must match the charger requirements.

The battery voltage must match the charger’s 
capabilities.

The battery capacity is within the charger’s range.

ELECTRICAL SAFETY

Safety regulations and requirements must be observed.

Safety devices installed on the electrical supply to the 
chargers must be of the proper type and rating. It is 
important to ensure that only fuses of the proper 
capacity should be used if they need to be replaced.

The equipment must be totally disconnected from all power
sources (mains supply and battery) before it can be opened
for inspection or servicing. The battery can only be discon-
nected after the charge has been stopped by pushing the
Stop/Start button. Access to the inside of the charger
should be restricted to authorized maintenance personnel. 

Please consult a qualified factory representative about any
problems or questions related to the installation of this
unit.

LIMITS OF USE

This charger is designed to be used in a sheltered area. 
It is designed exclusively to recharge lead batteries in an
industrial environment. 

PRODUCT  RECYCLING - DESTRUCTION

When this charger becomes obsolete, it can be recycled 
or destroyed by authorized facilities. Local regulations will
prevail and must be followed.

MODIFICATIONS AND IMPROVEMENTS

EnerSys reserves the right, at any time, to modify or 
improve its products, without any obligation to update 
this product or this manual accordingly.

The customer is not permitted to modify the product from
its original design and configuration (e.g. fitting additional
modules).
Any changes made by the customer could affect the 
product performance and invalidate the warranty.  

RECEIVING - STORAGE

Upon receipt, please inspect visually the exterior of the 
charger for any physical damage. If necessary, proceed 
within 24 hours with the usual claims procedure with the
transport company.

If the charger is to be stored before use, it should remain 
in the original packaging, carefully closed. Store in a clean,
dry area at a moderate temperature (0 °C to +40 °C). If the
equipment is stored at a temperature below 15°C, it must 
be gradually (24 hours) restored to operating temperature
before use, to prevent the risk of condensation that could
cause electrical faults and short-circuits.

INFORMATION PLATE

Located on either side of the charger.

EC DECLARATION OF CONFORMITY

EnerSys hereby declares that the chargers in the 
LifeSpeed IQ range covered by this declaration 
conform to European Directives:

Directive 2006/95/EC

(Low Voltage Directive):

EN60950-1

Directive 2004/108/EC

(ElectroMagnetic Compatibility):

EN61000-6-2, EN61000-6-4:
Immunity and emissions limits for industrial electronics
(class A- Industrial Environments)

Directive 2002/95/EC

(RoHS)

Safety and use instructions LifeSpeed IQ

TM

- 3-phase chargers

Summary of Contents for EnerSys LifeSpeed IQ

Page 1: ... requirements must be observed Safety devices installed on the electrical supply to the chargers must be of the proper type and rating It is important to ensure that only fuses of the proper capacity should be used if they need to be replaced The equipment must be totally disconnected from all power sources mains supply and battery before it can be opened for inspection or servicing The battery ca...

Page 2: ...econds Start an equalisation charge Access to a sub menu Access to the menus press 3 seconds Close the window UNPACKING The charger is delivered with the following 2 m AC mains cable 3 m DC battery cable This technical manual MECHANICAL INSTALLATION The charger is intended to be floor standing and must be installed in the vertical orientation The distance between 2 adjacent chargers should be at l...

Page 3: ...ows information relative to the connected battery and counts down the time remaining until the effective charge begins Ref Without Wi IQ With Wi IQ 1 Charger status CHARGE AVAIL DEFAULT EQUAL possible pump fault or DF4 2 Alternating display of battery voltage voltage per cell Ah restored charging time remaining charging time percentage of battery charge 3 Set up operating battery Battery temperatu...

Page 4: ...ion charge is indicated by the message EQUAL During the equalisation charge the charger displays the current ref 4 and alternating the battery voltage voltage per cell remaining time ref 2 2 The battery will be available as soon as the screen becomes green Automatic start If the equalisation charge has been programmed Configuration Equalisation menu the equalisation charge is initiated automatical...

Page 5: ...e BAT TEMP DF MOD WRG MOD IQ SCAN IQ LINK T NO Wi IQ Critical battery temperature One or more modules are not working correctly One or more modules are not the correct specification Looking for presence of Wi IQ Set the link Wi IQ Charger Low electrolyte level Default of balance voltage detected by the Wi IQ Too high battery temperature Preventive maintenance indicator The Wi IQ on the battery is ...