Hawk OptioLaser L100 Manual Download Page 2

Table of Contents

OptioLaser

 

L200

2

Table Of Contents

Overview  

3

Principle of Operation 

 

3

Applications  

3

Features  

3

Quick Start Guide  

4

Connections & Instructions for Safe Use   6

Connections & Instructions for Safe Use & Labels   

7

Laser Radiation Information 

 

7

Labels  

7

Apendix A 

 

8

Specifications  

8

Apendix B 

 

9

Dimension Drawings  

9

Part Numbering   

10

PROPRIETARY NOTICE

The information contained in this publication is derived in 

part from proprietary and patent data. This information has 

been prepared for the express purpose of assisting operating 

and maintenance personnel in the efficient use of the 

instrument described herein. Publication of this information 

does not convey any rights to use or reproduce it, or to use 

for any purpose other than in connection with the installation, 

operation and maintenance of the equipment described 

herein.

WARNING

This instrument contains electronic components that 

are susceptible to damage by static electricity. Proper 

handling procedures must be observed during the removal, 

installation, or handling of internal circuit boards or devices:

Handling Procedure:

1. Power to unit must be removed prior to commencement 

of  any work.
2. Personnel must be grounded, via wrist strap or other safe, 

suitable means, before any printed circuit board or other 

internal devices are installed, removed or adjusted.
3. Printed circuit boards must be transported in a conductive 

bag or other  conductive container. Boards must not be 

removed from protective container until the immediate time 

of installation. Removed boards must be placed  

 

immediately in a protective container for transport, storage, 

or return to factory.

>

<

Summary of Contents for OptioLaser L100

Page 1: ...Sultan Sonar Manual Rev 1 0 A Higher Level of Performance www hawkmeasurement com For more information please visit OptioLaser L200 Level Distance Position Measurement of Solids and Liquids Manual ...

Page 2: ...use for any purpose other than in connection with the installation operation and maintenance of the equipment described herein WARNING This instrument contains electronic components that are susceptible to damage by static electricity Proper handling procedures must be observed during the removal installation or handling of internal circuit boards or devices Handling Procedure 1 Power to unit must...

Page 3: ...plications Non contact measurement with laser technology Level distance position measurement of solids and liquids 303 Stainless steel housing Measurement range up to 100 m 328 Continuous measurement 10 mm 0 39 resolution NAMUR compliant 4 20 mA output 2 Normally open relay outputs Easy configuration via USB 220 110 V ac or 24 V dc power supply Visible aiming pointer Features OptioLaser L200 Appli...

Page 4: ...indow 8 If an automatic connection is not created click the Laser icon and select the appropriate USB port and 115200 baud rate 9 To access the configuration settings menu of the L200 press the CORRESPONDING key on the keyboard Menu Selection Default Description A 4 20 mA settings B 4 mA 25 00 m Enter the distance corresponding to the 4 mA output value C 20 mA 0 60 m Enter the distance correspondi...

Page 5: ...ter size 16 results If the Moving obstacle filter is ON this buffer allows for selection of the number of results used to reject obstacles W Visible aimer OFF Turns the visible aiming laser OFF or ON 10 Press the appropriate keyboard key to select a menu item e g type A for a Hide 4 20 mA settings to show or hide the 4 20 mA settings menu 11 To restart measurements press the SPACE keyboard key 12 ...

Page 6: ... emission from the aiming laser is Class 2 which indicates that the laser beam must not be stared at with the unaided eye CAUTION DO NOT STARE INTO THE BEAM The L200 should not be disassembled or modified in any way The laser eye safety rating depends on the mechanical integrity of the optics and electronics so if these are damaged do not continue using the L200 There are no user serviceable parts...

Page 7: ...rogramming USB Laser Safety Class 1M Class 2 aim Enclosure Rating IP66 Temperature 20 to 60 C 40 to 140ºF AU 61 0 3 9873 4750 US 1 888 429 5538 hawkmeasurement com OptioLaser L200 Laser Transmitter Company identification label Figure 2 Labelling on the OptioLaser L200 Specification Measuring laser s value AEL Aiming laser s value AEL Notes Laser wavelength 905 nm pulsed 670 nm CW Pulse width 20 ns...

Page 8: ... Length L200 180 mm 7 09 L200 DT 110 mm 4 33 Weight L200 2 7 kg 5 59 lb L200 DT 0 7 kg 1 54 lb Connection Flange accessory L200 DT with 4 Ø 8 5 mm holes on 120 PCD Housing material 303 Stainless steel Powder coated stainless steel Optical data Laser power Measuring laser 15 W peak Visible aiming laser 5 mW red Optical aperture 75 mm 2 95 Beam divergence 1 to half power points Lens material Impact ...

Page 9: ...1 Ø8 5 4 Holes on 120 PCD 140 5 51 3 Equi spaced holes tapped M5 on 74 PCD for front face mounting Laser optics Receiver optics Aiming pointer 64 09 2 52 3 7 1 4 6 120 4 72 USB connector Neutral 24 V dc Common Live 4 20 mA Earth Relay 1 Relay 2 COM 24 V Load Load Load 220 110 V ac power supply Figure 3 Dimension drawings of the L200 ...

Page 10: ...oLaser L200 Laser Transmitter for Level Model L100 OptioLaser Laser Level Transmitter up to 164ft L200 OptioLaser Laser Level Transmitter up to 328ft Dust Tube USB Programming Cable Required for every OptioLaser L100 L200 DT Dust Tube Stainless Steel Accessories Handheld Programmer Optional HP Handheld Programmer XX Not Required Accessories Swivel Bracket Optional SB Swivel Bracket XX Not Required...

Reviews: