Overview
Gladiator
Acoustic Switch Series
A Higher Level of Performance
Instruction Manual
www.hawkmeasurement.com
For more information, please visit >
SERIES 2000-RANGE-VALVE
Pressure and Level Transmitters
Page 1: ...erview Gladiator Acoustic Switch Series A Higher Level of Performance Instruction Manual www hawkmeasurement com For more information please visit SERIES 2000 RANGE VALVE Pressure and Level Transmitte...
Page 2: ...nting PA 5 PG9 cable gland 6 Electronics housing AISI 304 7 Hexagon nut SW 41 AISI 304 8 Stop AISI 316 9 O ring 2x VITON 10 Nipple SW 41 1 BSP M 2x AISI 316 11 Safety Lock AISI 304 12 M4 Bolt AISI 304...
Page 3: ...sing the auxiliary tool to ensure the parts are in line Use silicone grease 2 Tighten the valve bolts 18 4x 3 3 Remove the auxiliary tool and make sure the valve and be closed and opened easily 4 Make...
Page 4: ...libration All transmitters are fully calibrated at the factory to the conditions stipulated in users order When the buyer has not requested calibration the transmitter will be calibrated at the highes...
Page 5: ...supply is based on the total circuit resistance The maximum permissible load Ri max in case of 24 Vdc is 600 Ohm By increasing the power supply the external load can be increased to 1200 Ohm 36 Vdc s...
Page 6: ...bar is supplied to the transmitter the button must be held until the word SPAN appears on the display The transmitter is adjusted at 20 mA now The span can also be adjusted without test pressure see P...
Page 7: ...See Conversiontable P105 4 20 mA 20 4 mA Reverse output P106 Adjustment damping 0 to 25 sec P107 Indication of process temp Read out on display P108 0 C 1 F P109 Read out on display Curr 0 current 4...
Page 8: ...pressure P101 Span Adjustment 20 mA Without Test Pressure Before adjusting the span take care the right pressure unit is selected See also P104 and P109 Example Adjustment of the span at 0 2 bar First...
Page 9: ...smitters working with software revision 1 will direct process cancel mounting position P103 Adjustment Pressure Unit On Display See Conversion Table P104 104 Conversion Factor Display 1 1 000 mH2 O mW...
Page 10: ...on P107 until the actual pressure appears on the display again P107 Temperature In o C OR o F The temperature of the transmitter is standard adjusted at o C DEGR When pushing at h in P108 this will c...
Page 11: ...simulation Pressure simulation Unit To perform a pressure simulation follow the next steps 1 Push PROG until 100 is shown on the display 2 Push 10 times at h SPAN till 110 appears on the display 3 Con...
Page 12: ...rizontal tank Cilindric Push PROG until 100 is shown on the display 2 Push 11 x at h SPAN till 111 appears Confirm with PROG 3 Push h once Confirm with PROG 4 Enter the height H1 of the tank in meters...
Page 13: ...the length L of the tank For a ball or cone shaped tank take the cylindrical length plus the length of 1 ball cone Confirm with PROG 7 Enter H3 in meters if the transmitter is installed like in the le...
Page 14: ...al Cone From Software Revision 3 1 Push PROG till 100 appears on the display 2 Push 11 times at h till 111 appears Confirm with PROG 3 Push three times at h Confirm with PROG 4 Enter height H1 of the...
Page 15: ...confirm Lo Pr appears on the display 4 Push h i for adjusting to ON or OFF 5 Push PROG to confirm Adjustment Communication Protection 1 Push PROG till 100 appears on the display 2 Push h SPAN 13 times...
Page 16: ...H HART DTM This DTM is developed to make configuration changes of HAWK Series 2000 RANGE VALVE option H HART transmitters easy This DTM can be used with almost every FDT container To be able to insta...
Page 17: ...his is very important to prevent distortion of the weld spud The diaphragm of the SERIES 2000 RANGE VALVE is protected with a special protection cap Protect the diaphragm until installation takes plac...