SET UP AND OPERATION
Installation guide - read the safety instructions provided in
the user guide before activating the device.
• Mount the pan/tilt device on a horizontal and flat surface.
NOTE- When installing the Hawk Laser on a high post, please
ensure both buttons are switched on (pushed in) the main
unit before erecting.
• Do not
position the pan/tilt device on a surface which is
subject to vibration.
• Do not
use external force to stop the running of the pan/tilt
• Do not
allow laser beam to cross public roads, pathways,
footpaths or parking spaces.
• The Scan30 laser should be mounted and programmed in
such a way that people are not able to stare into the laser
beam.
• The rating protection of the Scan30 is IP65 so it can be used
both indoors and outdoors.
Installation
1. Mount the pan/tilt device
2. Mount the junction box on the wall
3. Plug in the connector of the Scan30 laser to T1 of the
junction box.
4. Connect P1J connector to DC 12V power supply.
5. Turn on Scan30 laser
6. Connect the controller to the communication port on the
Pan/Tilt or T2 of junction box to program the Scan30 laser.
7. The (speed) key is used to change the running speed of
the Pan/Tilt. The Pan/Tilt has 4 running speeds and should
ideally be set to the low speed for best results.
Note:
Pressing any key on the controller will be effective only when
the pan/tilt is not running. When the pan/tilt is running, pressing
any key on the controller will stop the pan/tilt. The key must be
pressed again to enter the command.
Operation
After power is turned on, the pan/tilt device with take approx. 30
seconds to seek the “origin” position. At this point the pan/tilt
cannot be controlled by the controller.
Once the pan/tilt device completes seeking the “origin” position,
the scan30 can be started to run one of the following 3 operation
modes:
1. Manual Mode:
Use the joystick to move the laser beam.
2. Scan Mode:
The laser beam sweeps back and forth without
changing in tilt direction. Scan mode can be started by
pressing the (scan) key on the controller.
3. Run mode:
The laser beam will move from one preset
position to another. The Scan30 has two running modes,
S mode and R mode. In S mode, the laser beam will move
according to the sequence of the preset position. In R
mode, the laser beam will run between the preset positions
randomly. Run Mode can be started by pressing the (Run)
key on the controller.
There is an Emergency Stop switch in the junction box, pressing
this switch will remotely shut down the laser. Clockwise rotation of
the switch will release the switch and turn the laser on again. The
Emergency Stop switch is the remote interlock of the Scan30 laser.
Programming the Preset Position Laser Control
The two keys (on) and (off) on the controller are used to enable
and disable the laser.
Pressing (on) will turn on the laser and (off) will turn off the laser.
Once the laser is turned off and the controller is unplugged from
the Scan30 laser, the laser cannot be turned on anymore. This
will prevent unauthorised people from turning on the laser. The
two keys (on) and (off) on the controller are used as the security
master control of the laser.
Programming the Pan/Tilt device
1. Connect the plug of the controller to the communication port
of the Scan30 or to the T2 connector of the junction box.
2. Use the joystick of the controller to steer the laser to the
desired position.
3. Press the numeric key and then
(Preset)
key to save the
position. For example: Press
(1)(Preset)
to save the No.1
position, then press
(2)(Preset
) to save number 2 position.
4. Repeat step 2 and step 3 to save more positions. A total of
16 positions can be saved, from No.1 to No.16.
5. Once you have your last position steer the laser back to the
origin start position or close to it and preset this as the final
preset number.
6. To remove all the preset positions, Press
(1)(2)(0)(Preset)
7. The keys
(S)
and
(R)
are running mode selections.
Press
(S)
then press
(Run)
, the laser will move forward from one
preset point to another preset point in Sequence No.1..No.2…
No.3…etc
Press
(R)
then press
(Run)
, the laser will move from one preset
point to another preset point in Random.
MAINTENANCE
Do not attempt to disassemble or clean the Hawk-Laser SCAN-
30 internally. This will invalidate the warranty.
The external surfaces should occasionally be wiped clean with a
soft cloth. Remove any external dirt or sand with a soft brush so
as to avoid scratching the finish.
Do not open, modify or attempt to service this product. Servicing
and repairs are to be arranged by the company you purchased
the unit from.
Troubleshooting
If you are experiencing problems during installation, please do or
check the following:
• Check power supply and voltage on battery output if using
12VDC.
• Ensure the temperature is not out of specification, otherwise
the diode laser will not work properly.
• Check the connection between Pan/Tilt device and controller,
disconnect plug of the controller and then reconnect.
• If the Pan/Tilt device is not working properly, power off and
on and then wait 30 seconds.
• Check the Emergency Switch is turn clockwise and on
(popped out)