Filling with hydraulic uid
The system to be connected is already lled with hydraulic uid free of air bubbles.
1. Open the tank lling screw.
2. Filter fresh hydraulic uid (Titan CHF 11S or Titan CHF 202). Recommended lter: 10 µm.
3. Turn the hydraulic power pack so that the tank points upwards.
4. Pour the ltered hydraulic uid into the tank.
Maximum permissible quantity (
see Chapter 10.1, "Technical data"
) can be read from the oil
level gauge if the installation position is horizontal. Use a dipstick if the installation position is
vertical.
5. Gently shake the hydraulic power pack so that the air bubbles pass into the tank.
✓
Wait a few hours until all the air bubbles are in the tank.
6. Operate the system with the hydraulic power pack 2-3x with low pressure until there is no more air in
the system.
7. Close the tank lling screw with a tightening torque of 6 + 2 Nm.
8. Assemble the hydraulic power pack in the intended installation position.
9. Vent the hydraulic system using the venting provisions on the consumer.
10. Correctly dispose of the hydraulic uid, hydraulic uid container and any cloths contaminated with
hydraulic uid.
5.3 Electrical connection
DANGER
Risk of fatal injury from electric shock
Touching live components directly or indirectly causes injury or death.
►
Electrical and electronic components must only be replaced and connected by trained specialist
personnel.
►
Obey all applicable electrical safety rules.
►
Only connect electric lines to the hydraulic system while the system is de-energized.
WARNING
Electrical and magnetic elds
Electrical and magnetic elds impair the functionality of cardiac pacemakers and implanted defibrilla-
tors.
►
People with pacemakers or implanted defibrillators must maintain a sufcient distance from
magnets.
►
Advise people with pacemakers or implanted defibrillators against approaching magnets.
►
Cordon off the area around the drive system and afx suitable warning signs to the barriers.