11.Vent the hydraulic system using the venting provisions on the consumer.
12.Check the hydraulic uid level in the hydraulic system.
Fluid level too low: top up with hydraulic uid
Fluid level too high: drain hydraulic uid
13.Properly dispose of the hydraulic uid, hydraulic uid container and any cloths contaminated with
hydraulic uid.
8.2.4 Replacing 2/2-directional seated valve SP3
Maintenance interval
In the event of malfunction.
Aids, tools, materials
■
Hex key, wrench size 5
■
New seated valve
1. Switch off the hydraulic system and secure it from being unintentionally switched on again.
2. Ensure that the system is depressurized.
3. Remove any component coverings.
4. Disconnect the connection cable from the coil of the solenoid valve.
5. Uninstall the seated valve.
6. Push in the new seated valve and screw on both cylinder screws M 6x12 with a tightening torque of
3+0.5 Nm.
7. Connect the connection cable to the coil of the solenoid valve.
8. Check the function of the solenoid valve by actuating.
9. Commission the hydraulic power pack.
24/34
B 6025 - 12-2021 - 1.1en
HAWE Hydraulik SE