7
Sensitivity Guide
Position Stem Tabs to Adjust Sprinkler Travel
1.
8
Adjusting Water Coverage
Metal
Wire
Clip
Stem
Tabs
Wide tabs produce
wide arc
Narrow tabs produce
narrow arc
- Set the sprinkler’s spray pattern to direct the water towards the desired
protection area.
Adjust the Water Spray
2.
Minimum
Maximum
Clockwise increases
spray distance
Counter-clockwise reduces
spray distance
- Turn the unit OFF, then fill the
Water Basin with tap/hose water.
- Fill
Water Basin to the top of the Water Fill Area. Spray Away™
Elite II holds approximately 3.5 gallons of water. Do not feed hose
into unit.
- Stand behind the
Infrared Sensor and turn the unit ON.
Wait 30 seconds.
- Wave your hand in front of the
Infrared Sensor to activate
Spray Away™ Elite II and ensure the arc and distance fit your
needs.
(Continuously activating the unit to test coverage area will significantly drain battery.
DO NOT test more than 3-5 sprays without allowing for recharge time.)
Start Repelling!
3.
Note:
Unit will not oscillate
when battery is low.
Testing the Sensitivity
IMPORTANT:
Test sensitivity area without water to ensure you do not drain battery.
- Turn unit to ON position; wait 30 seconds before moving in front of the sensor. During this
time, the unit is calibrating. Moving in front of
Infrared Sensor immediately after turning
unit ON will delay start up.
- Start outside your desired coverage area and walk from left to right in front of Spray
Away™ Elite II.
- Spray Away™ Elite II’s
Indicator Lights will illuminate for 3 seconds when it senses you.
Repeat this process until you are satisfied with Spray Away™ Elite II’s coverage area.
Note:
Spray Away™ Elite II will reset for 8 seconds between activations and will not detect.
2.
INDICATOR LIGHTS
FLASH WHEN
SENSING
DETERMINE
COVERAGE AREA
Animal Size
10 Feet
20 Feet
30 Feet
Small
9
9*
9*
Medium
8
9
9
Large
4
5
6
Setting the Sensitivity
- Using the Suggested Settings Charts,
adjust the
Sensitivity Knob accordingly.
1.
Setting the Sensitivity in Temperatures
BELOW 80 degrees F
Setting the Sensitivity in Temperatures
ABOVE 80 degrees F
SENSITIVITY
KNOB
Animal Size
10 Feet
20 Feet
30 Feet
Small
7
8*
8*
Medium
5
6
7
Large
2
2
3
Because Spray Away™ detects heat, the sensitivity must be set higher in warmer temperatures.
Please use the appropriate chart when temperatures reach 80 degrees F+.
Note:
In warmer temperatures, along with using higher sensitivity settings, the risk of false
triggering is higher. The sensitivity should be turned down in the case of false triggers.
*Some small
animals may
not be seen at
this distance
Distance
Distance
MOS-10290SprayAwayElite2013_II 2/28/13 8:54 AM Page 7