Page 8 / 13
EN-V233-0009-CA
Installing and using the HAUSSMANN RIRI keypad
Programming door-opening times
The time settings enable you to adjust the contact time for the CRT relays on door 1 and/or 2. This
duration (from 0.2 sec to 99 sec) is valid for the codes, the exit PB and the unrestricted-access
button.
To program the time settings for doors 1 and 2, proceed as follows:
ENTER PROGRAMMING MODE
Example: Opening time up to 0.2s.
TYPE:
Door 1 and 2
SET THE OPENING TIME
from 0 to 99
+
“2 beeps to confirm setting saved”
To program the time settings for door 1 only, proceed as follows:
ENTER PROGRAMMING MODE
Example: Opening time up to 15s.
TYPE:
Door 1 only
SET THE OPENING TIME
from 0 to 99
+
“2 beeps to confirm setting saved"
To program the time settings for door 2 only, proceed as follows:
ENTER PROGRAMMING MODE
Example: Opening time up to 99s.
TYPE:
Door 2 only
SET THE OPENING TIME
from 0 to 99
+
“2 beeps to confirm setting saved"
Note:
The factory default setting for door 1 and 2 opening times is 5 sec.
Check stored codes
"Is the memory empty?" by typing in the code
. The beep will vary depending on the
response.
ENTER PROGRAMMING MODE
-
response: 2 short beeps (YES)
-
response: 1 long beep
-
response: 1 short beep
Completely empty: no codes have been programmed.
Completely full: all codes have been programmed.
At least 1 code has been saved.
"Is a code available?" by typing in the code followed by . The beep will vary depending on the
response.
ENTER PROGRAMMING MODE
CODE
Example: Is the 9th code available?
TYPE IN THE CODE NO. and
01 to 59
-
response: 2 beeps (YES)
-
response: 1 long beep (NO)
Available
In use
+
Exit programming mode
When exiting programming mode, two short beeps sound and at the same time the green LED
lights up twice. The red LED goes out, thus confirming the return to normal operation.
Exiting programming mode is automatic:
1. after 30 seconds of no activity
2. when the button
on the keypad is pressed
Intelligent Security & Fire Ltd.