Step 2
Before doing any assembly, pre-test motors. Plug power cord into grounded wall outlet. The electrical rating for Series
1440 is 110V AC, 60Hz, 1.6 Amps. The 3-prong hospital grade grounded plug must be plugged in 3-pronged,
grounded, non-isolated, correctly polarized 110V AC receptacle.
Failure to do so could result in personal
injury or damage to equipment.
A. Step on UP button and elevate unit about 5” - 6”.
B. Step on DOWN button and lower down as far as it will go.
C. Step on UP button and elevate up to maximum height.
NOTE:
During the pre-testing, the green light on the Control Box should be on to indicate there is power to the control
box. If for any reason there is no response, see the trouble shooting guide on page 8 for possible problems - most
common of which is loose plug connections into control box.
You have completed initial test. Unplug power cord from power source as electrical power is not needed for remain-
der of assembly.
110V Power
Cord
Detail of Control Box
Green Light
Foot Control Cord and Plug
Underside of Control Box
Port for
Actuator A1
Port for
Actuator A2
110 V Power
Cord