background image

Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid.

Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, [email protected] • Errors and technical changes reserved.

english

... convincing solutions

3. Operating instructions

CAUTION! TOOLS MAY NEVER BE USED WITHOUT FIRST INSERTING THE PRESSING DIES.
Ensure that the pressing dies fit precisely to the appropriate area and are seated perfectly in
the holders.
OTHERWISE THIS MAY CAUSE SERIOUS DAMAGES OR BREAKAGES AND THE GUARANTEE
WILL BE VOIDED.

Preparation:

Before starting up the tool, read the operating instructions first. 
All current-carrying elements in the area you are working in should be disconnected.
Otherwise the protective procedures for working in the vicinity of 
components under current must be implemented. (DIN EN 50110)
Do not use the tool if you are tired or under the influence of medication, drugs or alcohol.
Take into account the valid accident prevention and safety regulations and use the tool exclu-
sively for the purpose for which it is intended.
Only electro-technically trained persons over 16 years of age may process connecting materi-
als using the tool.
The operating instructions must always be carried with the tool.
The instructions must have been read and understood by the user.
The operator must ensure that this is the case.

Operating:

• Select the appropriate pressing dies for the connection to be pressed.
• Insert the pressing dies in the tool head. All of the pressing dies that can be used in

Pushbutton

to advance

Die holder

Pushbutton for 
return movement

Summary of Contents for AH-12

Page 1: ...convincing solutions Electro hydraulic crimping tool AH 12 Art 216503 INSTRUCTION MANUAL Hydraulic crimping tools Video 216503...

Page 2: ...tee 2 year guarantee if used for the purpose it is intended 2 Area of work 2 1 Sensortechnology Pressing force in kN 120 kN Working pressure in bar 700 Opening Hub 20 mm Pressing width width Motorstop...

Page 3: ...protective procedures for working in the vicinity of components under current must be implemented DIN EN 50110 Do not use the tool if you are tired or under the influence of medication drugs or alcoh...

Page 4: ...o remove the inserts at the piston the steps listed above must be carried out in reverse order Start Bring the tool to the working position Select the appropriate pressing dies for the connection to b...

Page 5: ...ry as follows Connect the cable of the charger to a socket AC Inserting the battery into the charger Insert the battery firmly as shown in here until it touches the bottom of the charging compartment...

Page 6: ...Charger Instruction Li ion Batterie Voltage 18 V Weight 0 380 kg Length 120 mm Width 70 mm Height 80 mm Capacity Ah 3Ah Charge time 0 min Charge for Li ion Voltage 110V 220V Weight 0 430 kg Length 17...

Page 7: ...ect the battery voltage first and shows battery capacity rate when install battery 6 When battery charged completed the panel shows and comes beeping every 3 seconds 7 When the voltage is too low the...

Page 8: ...s sufficient Do not fill the tank with unsuitable oil or brake fluid Oil type VESTA HLP 15 from VERKOL or an oil of a similar quality Remove the tank lid and top up the oil The oil must be filtered fi...

Page 9: ...ely The oil must be drained and disposed of at the designated points Caution Hydraulic oils represent a risk to the groundwater Uncontrolled drainage or incorrect disposal carries penalties Environmen...

Page 10: ...parate armored cables The tools are not isolated and it is forbidden to work under tension HAUPA GmbH Co KG K nigstr 169 42853 Remscheid Germany Tel 49 2191 8418 0 Fax 49 2191 8418 840 Herewith we dec...