6 Maintenance
6
Maintenance
Clean the
MJ II
at intervals of no more
than 14 days.
The dirtier the enviroment, the shorter
the cleaning interval. Once the ionizing
and cleaning effect drops off, clean the
unit to bring the ionization and
cleaning effect back to normal.
ATTENTION
The ionizing unit may be damaged if
inappropriate brushes or cleaning
agents are used.
•
We strongly recommend the
exclusive use of
cleaning
accessories
from HAUG
GmbH & Co. KG. Refer to Section
Accessories.
13
Dry cleaning
1.
Switch off power pack and secure
against inadvertent operation.
2.
Switch off the compressed air
supply.
3.
Disconnect the ionizing unit from
the power pack.
4.
Brush the ionizing pins of the
ionizing unit using special
cleaning brush RB1.
5.
Blow off the
MJ II
with clean
compressed air (max. 6 bar).
6.
Check the high-voltage
connections and high-voltage
plugs for contamination. The
connections must be clean and
dry.
7.
Reconnect the ionizing unit to the
power pack.
8.
Switch the compressed air supply
back on.
NOTE:
If dry cleaning does not yield
the desired result, continue by using a
wet cleaning process.