background image

9

Art. Nr.: 5090020237 

Rev.: 00/2019-01-22

Contents

Publishing notes

Copyright © 2018 by 

 Hauff-Technik GmbH & Co. KG 

Dept.: Technical Editing 

Robert-Bosch-Straße 9 

89568 Hermaringen, GERMANY 

 

Tel.  

+49 7322 1333-0 

Fax  

+49 7322 1333-999 

E-mail 

[email protected] 

Internet 

www.hauff-technik.de

Reproduction of these installation instructions – even in ex-

tracts – in the form of reprint, photocopy, on electronic data 

media or using any other method requires our written consent.

All rights reserved.

Subject to technical alterations at any time and without prior 

announcement.

These installation instructions form part of the product.

Printed in the Federal Republic of Germany

Explanation of symbols

1

Work stages

Reference numerals in drawings

1

Effect/result of a work step

Required tool and auxiliaries

For proper installation of the multi-line building entry MSH 

Basic-FUBO-E/MSH Basic-MBK, the following tools and im-

plements are required in addition to the standard tools:

 

Torque wrench 1/4“+ internal hex socket wrench 6 

mm (e.g. Hauff MSH/GEH tool set)

 

Lubricant (GMT Art. No. 2790009100 or GML Art. 

No. 1591000754)

Preparing for assembly

(see Fig.: 1).

1

Align the MSH Basic-FUBO-E (basic unit) with the 

installation fixture based on the placement on the 

batter board and position. Align the basic unit level 

with the spirit level and insert into the ground (see 

Fig.: 3).

The precise height is not yet important.

2

Then release the wing screw, hold onto ground spike 

and remove MSH Basic-FUBO-E. 

Insert  the  included  impact  screw  into  the  ground 

spike and fasten with the wing screw (see Fig.: 4).

3

 Installation of the MSH-Basic-FUBO-E 

(basic unit)

After this, fit the MSH-Basic-FUBO-E (basic unit) and 

installation fixture together and fix with the wing 

screw (see Fig.: 2).

Legend for Fig.: 3

1

Inner side of wall incl. plasterwork 5 cm 

Strike the ground spike into the ground by approx. 

300 mm or until sufficiently firmly inserted (see Fig.: 5).

Remove impact screw again.

4

Place MSH Basic-FUBO-E (basic unit) upside down on 

the ground.

Spread sufficient GMT or GML lubricant on the lock-

ing sleeve side as well as on the sealing rings at the 

end of the pipes. (see Fig.: 6).

5

Insert KES hose systems with the locking sleeve side 

successively onto the pipe ends until they audibly en-

gage (see Fig.: 7).

6

Place MSH Basic-FUBO-E (basic unit) with mounted 

KES hose systems on the ground spike that has been 

driven into the ground (see Fig.: 9).

7

Then align the MSH Basic-FUBO-E (basic unit) with 

the unfinished floor height and position according to 

the batter board (see Fig.: 10).

After adjusting the height, fix the wing screw to fas-

ten the structure.

8

►  

MSH Basic-FUBO-E (basic unit) with mounted KES 

hose systems (see Fig.: 8).

MSH Basic-FUBO-E / MSH Basic-MBK

EN

 For precise positioning of the MSH Basic-FUBO-E 

(basic unit), a batter board must be prepared on site. 

The line ideally identifies both the upper edge of the 

unfinished floor and the wall inner side (see Fig.: 1).

 The installation fixture supplied is only for temporary 

fastening. Only the immediate filling with sand up 

to the level of the granular subbase gives a fixed 

positioning of the base plate implementation.

Publishing notes ................................................9

Explanation of symbols .....................................9

Required tool and auxiliaries ............................9

Preparing for assembly .....................................9

 Installation of the MSH-Basic-FUBO-E (basic 

unit) .......................................................................9

Installation of extension set ...........................10

 Installation of seal insert MSH Basic-MBK .....10

Summary of Contents for MSH Basic-FUBO-E

Page 1: ...the instructions prior to installation and keep them in a safe place www hauff technik de Immer Sicher Dicht Immer Sicher Dicht 2 Art Nr 5090020237 Rev 00 2019 01 22 Montageanweisung MSH Basic FUBO E...

Page 2: ...the instructions prior to installation and keep them in a safe place www hauff technik de Immer Sicher Dicht Immer Sicher Dicht 2 Art Nr 5090020237 Rev 00 2019 01 22 Montageanweisung MSH Basic FUBO E...

Page 3: ...0020237 Rev 00 2019 01 22 Art Nr 5090020237 Rev 00 2019 01 22 13 4 3 EN Notizen Notes 10 3 1 2 14 9 12 13 3 5 4 1 2 15 Oberkante Rohfu boden 16 MSH Basic FUBO E MSH Basic MBK 11 19 20 22 1 21 23 MSH B...

Page 4: ...0020237 Rev 00 2019 01 22 Art Nr 5090020237 Rev 00 2019 01 22 13 4 3 EN Notizen Notes 10 3 1 2 14 9 12 13 3 5 4 1 2 15 Oberkante Rohfu boden 16 MSH Basic FUBO E MSH Basic MBK 11 19 20 22 1 21 23 MSH B...

Page 5: ...13 W hrend des Auff llvorgangs mit Sand den Abstand zum Schnurger st sowie die senkrechte Position des Bauteils kontrollieren und gegebenenfalls anpassen Bei den Betonierarbeiten sind die jeweiligen l...

Page 6: ...pacing from the batter board and the vertical position of the component and adjust as necessary The relevant country specific standards and regulations are to be observed when carrying out concreting...

Page 7: ...t der Fl gelschraube fixieren siehe Abb 4 3 5 Montage MSH Basic FUBO E Grund k rper MSH Basic FUBO E Grundk rper und Aufstellvorrich tung zusammenstecken und mit der Fl gelschraube fixieren siehe Abb...

Page 8: ...rtigfu boden FFB bzw auf der Oberkante vom Grundk rper aufliegt siehe Abb 19 Danach den Dichteinsatz mit 2 Befestigungsschrauben am Grundk rper befestigen 4 Anschlie end die entsprechenden Medienleitu...

Page 9: ...stallation of the MSH Basic FUBO E basic unit After this fit the MSH Basic FUBO E basic unit and installation fixture together and fix with the wing screw see Fig 2 Legend for Fig 3 1 Inner side of wa...

Page 10: ...il the flange of the seal insert touches the finished floor height or the upper edge of the basic unit see Fig 19 Then fasten the seal insert to the basic unit with 2 attachment screws 4 After this pu...

Page 11: ...11 Art Nr 5090020237 Rev 00 2019 01 22 EN Notizen Notes...

Page 12: ...12 Art Nr 5090020237 Rev 00 2019 01 22 EN Notizen Notes...

Page 13: ...0020237 Rev 00 2019 01 22 Art Nr 5090020237 Rev 00 2019 01 22 13 4 3 EN Notizen Notes 10 3 1 2 14 9 12 13 3 5 4 1 2 15 Oberkante Rohfu boden 16 MSH Basic FUBO E MSH Basic MBK 11 19 20 22 1 21 23 MSH B...

Page 14: ...the instructions prior to installation and keep them in a safe place www hauff technik de Immer Sicher Dicht Immer Sicher Dicht 2 Art Nr 5090020237 Rev 00 2019 01 22 Montageanweisung MSH Basic FUBO E...

Reviews: