FUSION BATT
CODE YXC1
Circuit version
“SB39”
Flush when moving away
ELECTRONIC FLUSHING SYSTEM
FOR URINAL POD
ALKALINE BATTERIES (3X1,5V) OPERATED
FUSION BATT
VT 04/10
Rev. 2
A
ENG
CLEANING RULES
5
The urinal pod sensor’s boady is in STAINLESS STEEL AISI 316
therefore very resisitant to corrosive products. However it is
recommended, for cleaning the urinal pod to use warm water
and do not use abrasive detergents. To avoid damaging the
sensors do not use corrosive products or metallic, abrasive
sponges.
OTHERWISE THE WARRANTY WILL BE INVALID !
FIG. 8
• BEFORE USING THE PRODUCT READ CAREFULLY THE INSTALLATION INSTRUCTION AS WELL AS
THE ENCLOSED DRILLING DIAGRAM FOR MOUNTING THE CERAMIC URINAL POD TO THE WALL.
• HATRIA DECLINES ALL LIABILITY FOR DAMAGE OR INJURY CAUSED BY THE FAILURE TO FOLLOW ALL
THE INSTRUCTIONS PROVIDED IN THIS INSTRUCTION BOOKLET.
• THE PRODUCT'S OVERALL RELIABILITY AND DURATION ARE ENSURED BY CORRECTLY PERFORMING
ALL THE OPERATIONS PROVIDED IN THIS BOOKLET.
• KEEP THIS BOOKLET IN A SAFE PLACE.
• THIS PRODUCT MUST BE INSTALLED BY PROFESSIONALLY QUALIFIED PERSONNEL.
• THE PLUMBING SYSTEMS CONNECTED TO THE EQUIPMENT MUST COMPLY WITH THE STANDARDS
IN FORCE.
!
!
INSTRUCTIONS FOR CHECKING AND REPLACING BATTERIES
4
CHECK
The electronic flushing system
FUSION BATT
is fed by 3 low-cost and readily available
batteries • The batteries used are of alkaline type of 1.5 V-Size AA • The operation voltage is 4,5
Vdc (3 x 1.5V). • The batteries durability is approx. 4 years for 200 operations per day •
Do not
use rechargeable batteries
• Purchase
only
batteries that have a stamped expiry date which is
a minimum of 4 years after the date of your purchase. This will ensure a long durability of batteries
and a correct use of your electronic flushing system
FUSION BATT
. • Do not replace the
batteries with wet or damp hands, in damp places or with damp tools. •
Water must never be
inside the battery pack
otherwise batteries will be immediately discharged!
REPLACEMENT
When the red LED (2) (Fig. 2) starts to flash at regular intervals of 2 sec., it means that batteries
are being used up. However they will keep a residual period of operation which varies according
to the number of operations. To replace the batteries effect the following operations :
A) Disconnect (16) the battery pack and the circuit.
B) Remove the cover (19) of the battery pack by unscrewing 4 screws (20). Take the batteries out.
C) Insert the new batteries in the battery pack by paying attention to the polarity
+
and
-
.
D) Remount the cover of the battery pack paying attention at the gasket (21) in its seat.
E) At this point it may be reset the connection (16) between the battery pack and the circuit.
19
20
21
16
FIG. 7
OUT
ø
4
0
4
0
5
3
6
0
6
5
0
305
325
4
0
5
6
8
5
1
0
°
G
1
/2
MAX
FISSAGGI
IN
5
3
80
OVERALL DIMENSIONS
mm
fasteners
FIG. 9
IT IS RECOMMENDED TO EFFECT THE DISPOSAL OF THE USED UP BATTERIES ACCORDING TO THE NORMS IN FORCE
!
INSTALLATION AND MAINTENANCE
INSTRUCTIONS AND DRILLING DIAGRAM FOR
MOUNTING THE URINAL POD TO WALL
C
o
d
.
0
9
3
5
.E
N
G
Hatria S.p.A
tel. +39 059 384556 • fax +39 059 384212
[email protected] •
[email protected] • www.hatria.com