HATHOR

DAILY WEEKLY TIMER WITH 

PHOTO SENSOR

HATHOR-16TM SERVICE MANUAL

- upper voltage threshold setting;

- lower voltage threshold setting;

- time delay to turn OFF when high voltage detected (if voltage is

more than upper voltage threshold value);

- time delay to turn OFF when low voltage is detected (if voltage is

less than lower voltage threshold value);

- time delay to turn OFF when high voltage is detected (if voltage is

more than upper voltage threshold value);

- illumination level threshold setting.

Important notes:

Quality of the mains voltage power supply doesn’t influence on the
preprogrammed operation schedule of the HATHOR-16TM. So after the
normalization of the voltage parameters power load will be turned ON again,
but according to the time schedule preset by the user. If mains voltage was
absent not more than 1 month (device was disconnected for 30 days) all the
parameters and settings will be safely kept in the HATHOR-16TM memory.
Output contacts of the relay will be kept in a cold initial state. For example
HATHOR-16TM was preprogrammed such a way that every day of a week it
turn ON the power load at 22:00 and then at 8:00 in the morning of next day
it turns the power load OFF. Let’s assume that at 22:30 on Monday mains
voltage disappeared and then recovered back only on Wednesday at 6:00 in
the morning. So when voltage disappeared contacts 3-4 opened.

[email protected] 

www.hathorenergy.com

Summary of Contents for HATHOR-16TM

Page 1: ...HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM 1 info hathorenergy com www hathorenergy com...

Page 2: ...age variations in the mains with subsequent automatic re energizing after the mains parameters recovery Load energizing de energizing in accordance with the user set illumination intensity levels The...

Page 3: ...diode connection is also possible The HATHOR 16TM relay output terminals can immediately switch wattage load of up to 3 5 kW 16A When it is necessary to switch greater wattage a magnetic starter shou...

Page 4: ...ting the time of load cutoff tripping based on the lower voltage threshold Setting the time of load cutoff tripping after the mains parameters recovery Setting the illumination threshold In case of ma...

Page 5: ...unallowable voltage fluctuations are detected When the voltage returns back to normal parameters the device will automatically turn ON the power load equipment with the user defined time delay Turn ON...

Page 6: ...fferent independent sets of parameters SP1 SP2 and may delete any of these sets if necessary Thus the client may save in the device memory 2 different settings for curtain cases Output terminals of th...

Page 7: ...menu control buttons entry into menu parameter input save the parameter and menu exit scrolling buttons 5 8 wiring terminals 6 seven segment indicator display 7 green LEDs to indicate the operation m...

Page 8: ...8 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL 2 TECHNICAL PARAMETERS info hathorenergy com www hathorenergy com...

Page 9: ...R 16TM detects the unallowable OVER UNDER voltage then it will turn OFF the power load by opening the contacts 3 4 and in case of using the contactor that will turn OFF the power for the magnetic coil...

Page 10: ...e user may keep in the device memory to choose one of the available set of parameters SP1 or SP2 to clear delete current set of parameters PARAMETER SETTINGS to view the events parameters preprogramme...

Page 11: ...hedule of the HATHOR 16TM So after the normalization of the voltage parameters power load will be turned ON again but according to the time schedule preset by the user If mains voltage was absent not...

Page 12: ...y start up procedures include the following steps setting of the current time and the day of a week setting the schedule of events exact time values and days of a week when the power load should be tu...

Page 13: ...o the HATHOR 16TM it s necessary to connect mains voltage wires to 1 1 and 2 2 input contact terminals ATTENTION All connections of terminals should be performed strictly according to safety regulatio...

Page 14: ...ts for HATHOR 16TM it s necessary to connect the power load to the output contacts of HATHOR 16TM ATTENTION In order to prevent possible electric shock all the connections of the power load should be...

Page 15: ...15 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 16: ...16 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 17: ...17 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 18: ...18 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 19: ...19 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 20: ...20 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 21: ...21 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Page 22: ...the settings doesn t change so when viewing them on the display there will be shown all settings made those that are valid and the deleted not active events settings also To set the time schedule for...

Page 23: ...THE POWER LOAD IS LESS THEN 16A 3 5 KW THE RELAY MAY OPERATE WITH THE LOAD DIRECTLY VARIANT B IF THE POWER LOAD IS MORE THEN 16A 3 5 KW THE RELAY MUST OPERATE WITH THE POWER LOAD USING THE ADDITIONAL...

Page 24: ...ATHOR 16TM in manufacturer package should be stored in enclosed rooms at from 45 to 75 C and exposed to no more than 80 of relative humidity when there are no fumes in the air that exert a deleterious...

Page 25: ...25 info hathorenergy com www hathorenergy com...

Reviews: