background image

OPERATION

Form No. HBGm-1111

9

General

Use the following procedure to turn on and operate a Heated

Black Glass Shelf.

Read  all  safety  messages  in  the  IMPORTANT  SAFETy

INFORMATION section before operating this equipment.

Do not turn on unit until it has been cleaned thoroughly.

Ceramic glass surface must be clear of debris to prevent

burn-on.

Use only wipes, pads, and cleaners designed specifically

for cleaning ceramic glass surfaces. Using other wipes,

pads, or cleaners may damage ceramic glass surface.

Do  not  slide  pans  across  glass  surface,  use  rough-

bottomed  pans,  or  drop  anything  on  glass  surface.

Scratching  or  breakage  may  occur.  Damage  to  glass

surface  or  breakage  of  glass  caused  by  misuse  is  not

covered under warranty.

1. Using an appropriate cleaning wipe or a damp cloth, clean

the glass surface of the unit. Consistent daily cleaning will

keep cleanup easy as well as protect and preserve the

glass surface of the unit.

2. Plug unit into a properly grounded electrical receptacle of

the correct voltage, size, and plug configuration. See the

SPECIFICaTIONS section for details.

NOTICE

WARNING

Power ON/OFF 
(I/O) Switch

Temperature Control

Figure 9. Standard Control Panel

3. move the power ON/OFF (I/O) switch to the ON (I) position.

BURN HAzARD: Some exterior surfaces on the unit will get

hot. Use caution when touching these areas.

4. Turn the temperature control to the desired temperature

setting.

NOTE: Turning the temperature control clockwise will increase

the temperature setting. Turning the temperature control

counterclockwise will decrease the temperature setting.

5. allow the unit 30 minutes to reach operating temperature. 

NOTE: Refer to the 

OPTIONS aND aCCESSORIES

section for

installation and operation information for HBGB units

equipped with the flush mount control box.  

CAUTION

Summary of Contents for HBG-2418

Page 1: ...contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor...

Page 2: ...gurations 4 Electrical Rating Chart HBG models 5 Electrical Rating Chart HBGB models 5 Dimensions HBG models 6 Dimensions HBGB models 6 Installation 7 General 7 HBG models 7 HBGB models 7 Operation 9...

Page 3: ...n Authorized Hatco Service Agent or contact the Hatco Service Department at 800 558 0607 or 414 671 6350 fax 800 690 2966 or International fax 414 671 3976 WARNING BURN HAzARD Some exterior surfaces o...

Page 4: ...a built in unit that is equipped with an attached trim mounting ring The unit includes a remote mounted control box that is attached with 3 914 mm of conduit a 6 1829 mm cord with plug connects the co...

Page 5: ...Model Voltage Watts Amps Plug Configuration Shipping Weight HBGB 2418 120 425 3 5 NEma 5 15P 27 lbs 12 kg 220 230 CE 420 459 1 9 2 0 CEE 7 7 Schuko 27 lbs 12 kg 230 240 CE 459 500 2 0 2 1 BS 1363 or...

Page 6: ...mm 42 3 4 1086 mm 12 3 4 324 mm HBG 6018 60 3 8 1533 mm 18 3 8 466 mm 6 1 8 156 mm 54 3 4 1391 mm 12 3 4 324 mm HBG 7218 72 3 8 1838 mm 18 3 8 466 mm 6 1 8 156 mm 66 3 4 1695 mm 12 3 4 324 mm SPECIFIC...

Page 7: ...t for use make sure the countertop is level and strong enough to support the weight of the unit and food product make sure all the feet on the bottom of the unit are positioned securely on the counter...

Page 8: ...lant must be rated for use at a minimum temperature of 250 F 121 C Figure 8 HBGB Built In Installation Do not modify wiring or cut thermostat capillary on control box to increase remote mounting dista...

Page 9: ...ss surface of the unit Consistent daily cleaning will keep cleanup easy as well as protect and preserve the glass surface of the unit 2 Plug unit into a properly grounded electrical receptacle of the...

Page 10: ...rd CAUTION Burn Hazard Heated glass will be hot Use caution when touching this area 2 While unit is still warm wear an oven mitt and remove the bulk of the spill using paper towel 3 allow the unit to...

Page 11: ...relocate unit Unit not working at all Unit not plugged in Plug unit into proper power supply Unit not turned on move Power ON OFF I O switch to the ON I position Power ON OFF I O switch is not functi...

Page 12: ...g through the backside 4 Secure control box to surface using screws not supplied 5 Plug the control box into a properly grounded electrical receptacle of the correct voltage size and plug configuratio...

Page 13: ...nd shoulder washer to remove the rubber foot Figure 13 Installing the 4 Legs 6 at each corner of the base insert a 4 leg through the bottom of the base Place a nut on the leg stem inside the base and...

Page 14: ...ROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light bulbs h...

Page 15: ...15 Form No HBGm 1111 NOTES...

Page 16: ...on Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Service Plus Flan...