SANITIZING SINK HEATERS

Models 3CS-3, 3CS-4, 3CS-6, 3CS-9, 3CS-3B, 3CS-4B, 3CS-6B, 3CS-9B

The Hatco 3CS Sanitizing Sink Heater
makes manual warewashing faster and
more convenient. It maintains a continuous
supply of sanitizing rinse water without
taking up valuable sink space.

FLEXIBILITY

Designed to fit under the center of 
the sink, the 3CS is perfect for 3- or 
4-compartment sinks, pot and pan sinks,
and bar sinks.

The 3CS features a unique dual reservoir
system. One reservoir contains the
heating element and should always be
filled with water. The other reservoir 
traps and collects soil carried from other
sink compartments. This reservoir is
easily emptied after each use by a
convenient drain.

QUALITY

The following features assure the finest
performance for years to come:

• All models include stainless steel front,

powdercoated silver-gray hammertone
body, and convenient side drain.

• Every Hatco 3CS is equipped with an

ECO (Energy Cut-Off) wired into the
electrical circuit. This built-in protection
“breaks” the power to the elements if
the temperature of the water goes
above the normal thermostat setting.

• An on-off toggle switch activates the

heater and a yellow light indicates
when power is on. A red light is an
overtemp indicator pointing out the
need to refill the unit with water and
reset the unit.

• Each 3CS model features a stainless

steel tank with a five-year warranty.

• Available with an optional temperature

monitor or temperature light that
indicates when water reaches the
sanitizing temperature.

• The 3CS is shipped ready to install 

with all gaskets and fittings.

• Meets NSF Standard of 180°F (82°C)

for dish sanitizing.

Water

Inlet

Water
Outlet

Sump
Drain 

Drain

Handle

(Shown in closed

position)

Heating

Chamber

Drain

Front

WATER QUALITY REQUIREMENTS

Incoming water in excess of 3.0 grains of hardness per gallon (GPG)
(.75 grains of hardness per liter) must be treated and softened before
being supplied to water heater(s). Water containing over 3.0 GPG
(.75 GPL) will decrease the efficiency and reduce the operating life 
of the unit.

Note: Product failure caused by liming or sediment buildup is not

covered under warranty.