![Hastings TANKKD User Manual Download Page 6](http://html.mh-extra.com/html/hastings/tankkd/tankkd_user-manual_2106535006.webp)
Make sure the heater is not too far from the tank, maximum 50cm
Always place the 19KW heater lower than the tank, the 39KW may be placed at the same height, to guarantee
the natural flow.
Place the hose clamps on both ends of the heat hoses before installing
Place one heat hose on the inlet and bottom opening of the stove and tighten the hose clamps at both ends
securely.
Then place the other heat hose on the piece of the outlet, the other end on the top opening of the heater.
Tighten both of these securely with a wrench until it is also completely tight.
!!!:
Always but the stove on stable underground
Use dry wood
If you work without a pump there must always be natural circulation, otherwise the stove will overheat, resulting
in broken glass or complete collapse of the stove.
Do not leave the stove unattended.
At temp. below zero drain the heaters and pumps (taps are provided on both models).
You must always maintain a good fire to obtain optimal heating.
The heaters can become warm when connected without a pump. Be careful !
The chimney elements are always placed seam on seam and slide together very easily if you place the right
sides together. Do not FORCE these.
Always use sealing rings with the coupling pieces!
We supply 3 m heat hose when installed with a pump. If you want longer ones, you can alway order extra