1
DRILL TWO HOLES INTO WALL
FIT SUPPLIED RAWL HOOKS
HANG MAIN UNIT ON HOOKS
NOTE: UNIT IS WALL
MOUNTED
PLUMB UNIT INTO WATER
SUPPLY AS PER PLUMBING
DIAGRAM
FILL UNIT WITH WATER
BEFORE APPLYING
ELECTRICAL POWER TO UNIT
ENSURE ALL AIR IS OUT OF
UNIT BY OPENING HOT
WATER OUTLET TO ALLOW
AIR TO ESCAPE
2
FIT GENERATOR UNIT ON
LEFT SIDE OF UNIT.
PLUG INTO WALL SOCKET
CONTROLS WILL FACE TO
REAR
NOTE: LEFT UNIT WILL
SWITCH ON
AUTOMATICALLY. NO
NEED TO PRESS THE
POWER BUTTON
ONLY ON 50L 2+2KW
UNITS
3
FIT GENERATOR UNIT ON
RIGHT SIDE OF UNIT.
PLUG INTO WALL SOCKET
NOTE: UNIT WITH SPEC
LABEL IS RIGHT SIDE
MASTER UNIT.
DOUBLE SOCKET WITH
25AMP CB and 2.5mm
CABLE TO BE USED ON 50L
2+2KW UNITS
ALLOW 150MM FREE SPACE
AROUND INTAKE/EXHAUST
DUCTS
4
SWITCH ON AT WALL PLUGS
INDICATOR LIGHT ON RIGHT
UNIT WILL FLASH
ONE BEEP WILL SOUND
38 WILL APPEAR ON DISPLAY
ON RIGHT SIDE & WATER
TEMP AFTER 5 SECONDS
5
PRESS POWER BUTTON
ONCE UNIT WILL START
75 SHOWS ON DIGITAL
READOUT FOR 5 SEC
TEMP SHOWS AFTER 5 SEC
6
UNIT WILL HEAT TO 75° C
TO ADJUST TEMP SETTING
PRESS TEMP BUTTON –
TEMP SETTING WILL SHOW.
PRESS TO CHANGE TEMP
SETTING BY 5 DEG FROM
40-75 DEG
INSTALLATION DIAGRAM CN30L
NOTE:
COLD WATER SUPPLY SHOULD COME FROM ABOVE UNIT TO PREVENT
UNCONTROLLED DRAINAGE
1)
THIS UNIT MUST BE INSTALLED AS PER THE DIAGRAM
2)
THIS IS A WALL MOUNTED UNIT (HORIZONTAL ONLY)
3)
NOTE: IT CANNOT BE POSITIONED UPRIGHT OR LAID DOWN ON A SHELF OR THE
FLOOR
4)
ENSURE THE T\P VALVE IS PLUMBED TO THE DRAIN OR ATOMSHPERE IN A SAFE
AREA
5)
A THERMOSTATIC TEMPERING VALVE MUST BE USED IF THE TEMPERATURE IS
SET ABOVE 60 DEG.
6)
THE MULTI VALVE MUST BE AN APPROVED MAKE AND A
400 KPA
VALVE IS
RECOMMENDED
7)
ENSURE THE ELECTRICAL SUPPLY IS CAPABLE OF 22 AMPS WITH 2+2 KW UNITS
(Min 2.5mm² cable)
8)
DO NOT REMOVE 15 AMP PLUG – WARRANTY IS AFFECTED
9)
DRIP TRAY REQUIRED IF INSTALLED IN ROOF OR CUPBOARD
10)
ALLOW 150mm OPEN AREA ON GENERATOR FAN DUCTS