For connect to CML00 please write the true network address, or click of the “Search IP” –
Button.
Figure 5-5:
Window “Search” in SYScontrol
All CML00 located in the network are displayed.
For connection, click on device and
“OK”
6
CML setup via “snmp”
Only a small part of general SNMP OIDs is implemented.
For new CMLs, please use the HEL-CRATE-MIB.txt!
-
With command “snmpwalk” OIDs are all listed, for example:
C:\>snmpwalk -v 2c -m + WIENER-CRATE-MIB -c guru 192.168.1.9 crate
-
With command “snmpget” is only a certain OID listed, for example:
C:\>snmpget -v 2c -m +WIENER-CRATE-MIB -c guru -t 0.01 -r 10 192.168.1.9
sensorWarningThreshold.temp1
-
With command “snmpset” is only a certain set OID, for example:
C:\>snmpset -v 2c -m +WIENER-CRATE-MIB -c guru -t 0.01 -r 10 192.168.1.9
sensorAlarmThreshold.temp1 i: 45
A detailed description of the SNMP functionality can be found in the corresponding MIB file
HEL-CRATE-MIB.txt or (old solution WIENER-CRATE-MIB.txt)