Page 1: ...MyWatt SEM3000 Series Operation Manual Version 6 6 July 1st 2019 Thank you for choosing MyWatt SEM3000 Series Smart Energy Monitor and Logger with web cloud service ...

Page 2: ...10 model You can download the data to pc by software Or you can upload the data with 1minute interval to the web server through TCP IP connector We also provide web cloud service through http mywatt org Options 2019 delivery Please add 50 more on SEM3110 price SEM3500 model 10 channels for 4months data logging with 5minutes log interval to wireless receiver 2 SEM300 Series Model 1 accuracy with vo...

Page 3: ... installation please ensure you have 1 An electricity bill with details of your tariff and rates 2 A small cross head or flat bladed screwdriver Please connect the AC power adapter to the power linking hole of CRT3000 transmitter You can use 10years continuously without battery Do not use the battery if available AC power Or remove the battery compartment cover and insert the C type alkaline batte...

Page 4: ...for the clock backup or 3days data display on lcd glass when necessary It is not necessary for normal use 1 Press and hold the CHECK key 5 seconds on the rear side of the CRT3000 wireless transmitter until the red LED flashes rapidly If you are using PIT3000 wireless transmitter press SET button at the front side of PIT3000 until the red LED flashes rapdly 2 Please check the lcd display is in stan...

Page 5: ...ge the voltage with UP DOWN key But if you are using 100V please change it with UP DOWN key to 100V If you are using 230V please adjust the voltage what you want or 5 Press the CHANGE key of display unit for to finish the pairing process The radio wave icon in the top lefthand corner of the main screen will show radio wave power strength from this time The two units will be linking within 2 minute...

Page 6: ...crease and decrease difference on every 2 seconds Additionally it also shows the energy consumption percentage vs monthly target on every 10 seconds You can adjust the monthly target by C8 calibration mode Top left side shows the energy billing method selection from 0 to 2 0 is the single tariff rate selection 1 is 4 step tiered tariff rate selection 2 is special rate tariff selection For USA plea...

Page 7: ...one of the keys MENU CHANGE DOWN UP CHANNEL and SET We recommend you use the sound to help you program the settings accurately LCD protection cover film Please take off the scratched cover film when you use it You can see more clear display CALIBRATION MODE C1 C11 Before calibration please see the lcd display must be as below photo A TIME CLOCK C1 1 Press and hold the MENU key until you hear a bee...

Page 8: ... once to change C1 C2 3 Press SET key to see F blinking to see 0 Press UP DOWN key to select 0 2 0 Single Rate Flat Rate 1 4 step Tiered Rate 2 Time of Use Rate for all week 7 Day 3 Time of Use Rate for weekdays weekend 4 Press CHANGE to go normal display C TARIFF RATE FOR SINGLE FLAT RATE C3 1 Press MENU key for to change CHANNEL SET 2 Press the SET key 3 seconds to see F C1 symbol Press MENU key...

Page 9: ...AYS MO FR MID PEAK 0 16 KWh WEEK ENDS SUNDAY SATURDAY ON PEAK 0 24 KWh 1 Press MENU key for to change CHANNEL SET 2 Press the SET key 3 seconds to see F C1 symbol Press MENU key to change C1 C5 3 Press SET key to see MON TUE WED THU FRI and F COST is blinking Please change the MID PEAK COST 0 16 KWh Press SET to change ON PEAK COST 0 24 KWh 4 Press SET key to change OFF PEAK COST 0 10 KWh 5 Press ...

Page 10: ... key 3 seconds to see F C1 symbol Press MENU key 8 times to change C1 C9 3 Press SET key to see F blinking and 0 V Press UP key continuously until you reach 100V AUTO V 4 Press CHANGE to store If you are using Channel 2 10 with PIT3000 Your CRT3000 Channel e g No 1 will get the Voltage value from PIT3000 automatically when you set the Voltage as AUTO J TEMPERATURE unit change C10 Your default sett...

Page 11: ...an 1 00 you must adjust the power factor Wattage Voltage x Current x Power Factor 1 Press MENU key for to change CHANNEL SET 2 Press the SET key 3 seconds to see F C1 symbol Press MENU key to change C1 C14 3 Press SET key to see F blinking Press UP DOWN key to adjust the correct number 4 Press CHANGE to store It takes 20 seconds O GREEN HOUSE GAS UNITS Your SEM3000 can calculate the amount of CO2 ...

Page 12: ...o slide along the cable Fix the mounting bracket optional to the wall or the baseboard used to mount your meter next to the fuse box or nearby Slot the Transmitter into its bracket and connect the Sensor cable to any one of the three Transmitter sockets located on the base of the unit You can connect 3 clamps for 3 phase applications AC power adapter is needed CONGRATULATIONS You have now set up a...

Page 13: ...will see the web cloud service graph immediately If you are using MyWatt Cloud SEM3110 Model you can upload all the data to the Web Cloud Server by using LAN cable You can upload the data every 1 minute interval If you connect the Power Adapter and LAN cable to the SEM3110 receiver you SEM3110 clock will be calibrated automatically In this case you do not need to calibrate the clock by manually We...

Page 14: ...M3110 serial number on the website And your web cloud service will follow within 10 to 15 minutes after the LAN cable connection to the internet and will show the following graph at first You can see the sample http mywatt biz cloud ...

Page 15: ...ntains a radio transmitter which may affect the operation of medical or emergency equipment Before using this equipment in a medical environment always seek the advice of a qualified medical expert The LCD screen is made of glass and may break if dropped Please take special care when handling a damaged Display screen as the liquid crystals may be harmful to your health Do not cover the ventilation...

Page 16: ...t hyh korins kr to report the issue and reason for returning your product Korins Inc will issue you a form and reference number Once we have received the completed form and proof of purchase we will commence the returns process COMPLIANCE The CE marking certifies that this product meets the main requirements of the European Parliament and Council Directive 1999 5 EC A copy of the signed and dated ...

Page 17: ... unit s memory by following these instructions See STEP 2 for the pairing resetting LCD Touch key of CHANGE UP and DOWN is not working please press MENU button USB Power Adapter Rating 5Vdc 50mA INSTALLING SEM3000 FOR 3 PHASE MEASUREMENT If you have a 3 phase power supply you need 3 CT clamps and possibly larger size clamps depending on the size of your cables a Installing SEM3000 in USA JAPAN for...

Page 18: ...ower adapter 125 CRT3000 Series Wireless Transmitter RF433MHz for 3 Phase in USA We have 3 different type http www mywatt biz model index2 htm 1 CRT3000 transmitter with 3pcs of 30A or 75A clamps and AC power adapter 70 2 CRT3001 transmitter with 3pcs of 200A clamps and AC power adapter 100 3 CRT3005 transmitter with 3pcs of 500A clamps and AC power adapter 165 attention CRT3000 CRT3001 and CRT300...

Page 19: ... electricity is called a tariff and is clearly identified on your electricity bill Some electricity users will have primary secondary rates based on usage To make use of this data you will need to calculate an average based on usage and enter this figure into tariff 1 HOW MUCH DATA CAN BE STORED ON MY SEM3000 1 Data will be log to the SEM3000 receiver for the last 900 days as hourly value of elect...

Page 20: ...ons 1 1 minute interval real time data display to the PC and automatically data logging on PC 2 SEM3000 logged data down load function by selecting the download start time Simply connect the pc cable between SEM3000 and PC with specially made mini USB cable only ...

Page 21: ...att30 You can find mywatt30 app from Android shop or Apple shop Korins Inc http mywatt biz web server http mywatt org You can use web server ID and Password for App operation 1 2 3 You can log on your existing ID You can see linked devices list and You can see each channel data ...

Page 22: ...a at a time 4 5 6 Each channel data display In the future we will add voltage current power factor temperature humidity pressure and others up to 10 items For example SEM250WIFI SEM300WIFI Hour Day Month energy and money display Hour Day Month energy and money display 7 8 9 ...

Page 23: ...Change Nickname Change Device Name Change Channel Name 10 Channels Energy Logger Set with 10 to 30pcs clamp ...

Page 24: ......

Page 25: ...New Real Power MyWatt Energy Loggers 1 accuracy SEM250WIFI Single Phase 3 channel Smart Energy Logger ...

Page 26: ...0 RS 485 Software free SEM270LCD WIFI model will be available September 2019 https www youtube com watch v lTHPLNFtXhw SEM330 Smart Energy Logger 3 Phase 4 Line Voltage Energy Logger with 3 clamps 1 accuracy ...

Page 27: ...SEM360LCD WIFI Smart Energy Logger https youtu be TTNHDYOKcQI SEM370LCD WIFI Smart Energy Logger for rail mounting https youtu be JH4FUTWXMB8 SEM370 SD CARD ...

Page 28: ...SEM370 Menu Button ...

Page 29: ...web cloud service rs 485 software App service ...

Page 30: ...optional software extra price Option 1 Option 2 up to 300 channels Smart Energy Monitoring System for BEMS FEMS ...

Page 31: ...ll mounting portable 1 accuracy BEST SELLER SEM375 have magnet on backside and you can attach it onto the steel plate SEM375 have battery clock backup device You can keep clock 2 months without power SEM390 4CH model https youtu be uky0y1xMfQg ...

Page 32: ...ld connect up to 12 clamps Smart Plug SEM200 SEM210 Smart Plug 40 00 WIFI version Unlimited Timer setting SEM810 Smart Aircon Controller 50 www mywatt biz hyh korins kr mobile 82 10 8905 1244 David Hong Chairman ...

Reviews: