3 Block MEASURED VARIABLES
Device Functions Proline Promag 55
22
Hauser
REFERENCE
TEMPERATURE
(0701)
Use this function to enter the reference temperature for the programmed density value.
User input:
5-digit floating-point number
Factory setting:
20 °C
!
Note!
The appropriate unit is taken from the UNIT TEMPERATURE function (0422)
(s. Page 18).
EXPANSION
COEFFICIENT
(0702)
Use this function to enter a volume expansion coefficient (× 10
–3
in 1/K) for
temperature-dependent density changes.
User input:
5-digit floating-point number (× 10
–3
1/K)
Factory setting:
0
!
Note!
This function is only displayed if the current input is set to "TEMPERATURE"
(s. Page 108).
Function description
MEASURED VARIABLES
➞
SPECIAL UNITS
➞
DENSITY PARAMETER