WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 3 Operation and Adjustments
3.6.2
PA Meters
This screen is accessed by pressing the “PA Meters” button in Figure 3-6 or Figure 3-7.
A complete set of PA Meter readings is given in the Factory Test Data. The Factory Test
Data readings are taken at rated power unless otherwise specified by the customer. Any
reading out of tolerance will be reported as a fault to the control system and show up on
the PA Faults screen in Figure 3-7.
Figure 3-8 PA Metering Screen
The following table gives typical readings (at 600W output) and fault limits for each
reading. See factory test data for more accurate readings for your transmitter and
frequency.
Table 3-2 PA Module Typical Readings and Fault limits
Reading
Typical Reading
Fault Limit
RF Input
15mW
0 = underdrive / 23mW = Overdrive
RF Output
600W
none
Reflected
Less than 10 watts
Fault = 200W
Power Supply Voltage
32Vdc
Under V = 30V / Over V = 33V
Total Module Current
55 - 65 amps
75 amps
Driver Pallet Current
6 - 7 amps
12 amps
PA Pallet Currents
8 - 10 amps each
12 amps
Heatsink Temperature
60 - 65
o
C (affected by ambient)
90
o
C
*Current readings will vary with frequency and power output.
To Figure 3-9
To Figure 3-7
To Figure 3-7
Summary of Contents for Ranger Series
Page 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Page 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 7: ......
Page 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Page 11: ......
Page 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...