Table 4-3 PA Control Distribution
PA Designations on PA
Controller Schematics
PA
Designations
PAC
#1
PAC
#2
PAC
#3
PAC
#4
PA Designations on
Combiner and
Divider Schematics
Related
Isolation
Relay #
Related
Isolation
Resistor #
A1
PA6
PA8 (J8)
K8
RT8
A2
PA5
PA7 (J7)
K7
RT7
A3
PA8
PA6 (J6)
K6
RT6
Z-PLANE A
A4
PA7
PA5 (J5)
K5
RT5
A5
PA3
PA1 (J1)
K1
RT1
A6
PA4
PA2 (J2)
K2
RT2
A7
PA1
PA3 (J3)
K3
RT3
A8
PA2
PA4 (J4)
K4
RT4
B1
PA5
PA5 (J5)
K5
RT5
B2
PA6
PA6 (J6)
K6
RT6
B3
PA7
PA7 (J7)
K7
RT7
Z-PLANE B
B4
PA8
PA8 (J8)
K8
RT8
B5
PA4
PA4 (J4)
K4
RT4
B6
PA3
PA3 (J3)
K3
RT3
B7
PA2
PA2 (J2)
K2
RT2
B8
PA1
PA1 (J1)
K1
RT1
C1
PA6
PA8 (J8)
K8
RT8
C2
PA5
PA7 (J7)
K7
RT7
C3
PA8
PA6 (J6)
K6
RT6
Z-PLANE C
C4
PA7
PA5 (J5)
K5
RT5
C5
PA3
PA1 (J1)
K1
RT1
C6
PA4
PA2 (J2)
K2
RT2
C7
PA1
PA3 (J3)
K3
RT3
C8
PA2
PA4 (J4)
K4
RT4
D1
PA5
PA5 (J5)
K5
RT5
D2
PA6
PA6 (J6)
K6
RT6
D3
PA7
PA7 (J7)
K7
RT7
Z-PLANE D
D4
PA8
PA8 (J8)
K8
RT8
D5
PA4
PA4 (J4)
K4
RT4
D6
PA3
PA3 (J3)
K3
RT3
D7
PA2
PA2 (J2)
K2
RT2
D8
PA1
PA1 (J1)
K1
RT1
This chart is meant as an aid in tracking control, status and metering signals between the PA Controllers and the
individual PAs. The first column groups the PAs by Z-Plane. The second column gives the actual PA
designation or location as silk-screened on the inside of the PA doors. As for columns 3 through 6, each PA
Controller is identical and has the ability to control 8 PAs, PA1-PA8. However, an output labeled PA1 on the
PA Controller schematic does not necessarily go to amplifier A1 or B1. For example, On Z-Plane A, amplifier
A4 is connected to any input or output of PAC #2 that is labeled PA7, such as PA7_GATE. Note that on Z-
Plane B, amplifier B4 is connected to any input or output labeled PA8 on PAC #1. This cross numbering is due
to the fact that Z-Plane B is inverted compared to Z-Plane A. The seventh column is actually the intermediate
step between the PAs and the PA Controllers and gives the designation and connector number for each of the
PAs. The last 2 columns give the component designator for the Isolation Switch and Isolation Resistor for each
of the PAs. The Isolation switches and resistors are located on the Isolation boards mounted on the sides of the
Z-Planes.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...