WARNING: Disconnect primary power prior to servicing.
Section 4 Overall System Theory
Platinum Z16HD+
when the transmitter is turned off. When the discharge circuit is active, it disables the
SCRs to prevent the supply from trying to turn on during a discharge cycle.
Figure 4-9 Simplified 3-Phase PA Power Supply Soft-Start and Discharge
4.5.1.2
Single Phase Power Supply
The Z16HD+ single phase transmitter uses four main power transformers working in
groups of two. These are designated PS1, PS2, PS3 and PS4. Figure 4-10 shows the
placement of each of the 4 power supplies and connection points for installation or
removal of the supplies. Due to the size of the single phase supplies a second cabinet is
required for PS3 and PS4. This requires that each cabinet have separate AC line feeds
from separate wall breakers and some interconnections between the cabinets.