2.5
Electrical Installation
2.5.1
Grounding
Located in the lower left rear corner of the cabinet is a ground
strap. Connect the station ground to this strap with 2 inch (5 cm)
copper strap. For additional information on station grounding
requirements refer to Appendix C.
GROUND STRAP CONNECTED
2.5.2
Primary Wiring
(Refer to drawing 839-7994-179.)
AC power is connected to terminal block 1A14TB1 located on
the right wall inside the rear door. Use #8 AWG wire at a
minimum or larger if required by Wiring Codes. Connect the
“hot” side of the ac line to 1A14TB1-1, the neutral side to
1A14TB1-2 and connect 1A14TB1-3 to the safety or protective
ground wire.
PRIMARY WIRING CONNECTED
SYMBOL
FUNCTION
CONNECTOR LABEL
CONNECTOR TYPE
Exciter A
Exciter B
J1
J11
Video Input
VIDEO IN
BNC
J2
J12
Aural Composite input
COMP AUR
BNC
J3
J13
Aural Subcarrier 1
AUR SCA 1
BNC
J4
J14
Aural Subcarrier 2
AUR SCA 2
BNC
J5
J15
Precise Frequency Control Input
PFC IN
BNC
J6
J16
Monaural Aural Input/Dual Sound Audio 1 MONO AUR 1
XLR
J7
J17
Monaural Aural Input/Dual Sound Audio 2 MONO AUR 2
XLR
J8
J18
NICAM Reference
BNC
J9
J19
NICAM IF In
BNC
J10
J20
Option Access
BNC
J21
Remote Command Input
37 Pin D
J22
Remote Status Output
37 Pin D
J23
Remote Analog Output
37 Pin D
Table 2-2. Input Signals & Remote Conrol I/O
1A2 Exciter Meter/Control Board
JP #
POSITION
FUNCTION (AS SHIPPED)
JP1
1-2
Loss of video enabled
JP2
1-2
Remote control of aural group delay
JP3
1-2
Remote control of notch diplexor
1A3 Interface Logic
JP#
POSITION
NORMAL FUNCTION
JP1
1-2
Visual foldback enabled
JP2
1-2
Aural foldback enabled
JP3
1-2
Aural AGC enabled
JP4
1-2
Source/Sink for Remote Status
JP5
1-2
Source/Sink for Remote Command
JP6
Factory Select Aural AGC 2dB pad select
JP7
1-2
Exciter A fault select DIGITAL
JP8
1-2
Exciter B fault select DIGITAL
JP9
1-2
Power supply 3 not present
JP10
1-2
Video control enabled
JP11
Factory Select Aural AGC 3dB pad select
JP12
1-2
Aural AGC enabled
JP13
Factory Select Visual AGC 3dB pad select
JP14
Factory Select Visual AGC 2dB pad select
JP15
1-2
NO 5 sec restart, AC FAIL
JP16
1-2
High VSWR shutdown enabled
Table 2-3. Setup Jumpers - Normal Positions
Platinum™ Series
2-4
888-2457-001
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Platinum HT EL 2000HS
Page 4: ...This page left blank intentionally ...
Page 6: ......
Page 8: ...ii ...
Page 12: ...This page left blank intentionally ...
Page 38: ...This page left blank intentionally ...
Page 46: ...This page left blank intentionally ...
Page 54: ...This page left blank intentionally ...