NEXIO AMP MDR Connector Assembly
This section describes the procedure for assembling a NEXIO AMP MDR connector.
To assemble a MDR connector
1
Use a wire stripper to remove approximately 1/16” of the wire insulation from each
of the required conductors (see
).
Figure 6-3
Stripped Wires
2
Solder wire 1 to pin 1 on the connector. To locate pin 1, see
.
Figure 6-4
MDR Connection Pin Locations